Amperometric flow-injection determination of phenolic compounds at self-assembled monolayer-based tyrosinase biosensors

被引:125
作者
Campuzano, S [1 ]
Serra, B [1 ]
Pedrero, M [1 ]
de Villena, FJM [1 ]
Pingarrón, JM [1 ]
机构
[1] Univ Complutense, Fac Ciencias Quim, Dept Quim Anal, E-28040 Madrid, Spain
关键词
self-assembled monolayers; tyrosinase; flowing systems; gold disk electrode;
D O I
10.1016/S0003-2670(03)00919-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of a tyrosinase (Tyr) biosensor, constructed by immobilisation of the enzyme by cross-linking atop a 3-mercaptopropionic acid (MPA) self-assembled monolayer (SAM) on a An disk electrode, is reported for the amperometric detection under flow-injection (FI) conditions of several phenolic compounds (phenol, catechol, m-cresol, p-cresol, 4-chloro-3-methylphenol, 3-chlorophenol, 4-chlorophenol, 2,4-dimethylphenol, 3,4-dimethylphenol, and 2-aminophenol). Experimental variables such as the detection potential (-100 mV versus Ag\AgCl\KCl 3 M), flow rate (1.02 ml min(-1)), injection volume (350 RI), and pH of the carrier solution (0.05 M phosphate buffer of pH 7.0) were optimised. Under these conditions, the Tyr biosensor exhibited a good reproducibility of the FI measurements, with no need to apply a cleaning or pre-treatment procedure. The useful lifetime of one single biosensor was 5 days. The kinetic parameters of the Tyr reaction were calculated for the 10 phenolic compounds. The analytical performance of the Tyr-MPA-Au electrode under flow through conditions was compared with that of other Tyr electrochemical biosensors reported in the literature. The usefulness of the biosensor for the analysis of real samples was proved by performing the estimation of the content of phenolic compounds in waste waters from a refinery at three different stages in the waste purification process. (C) 2003 Published by Elsevier B.V.
引用
收藏
页码:187 / 197
页数:11
相关论文
共 26 条
  • [1] High-performance liquid chromatographic determination of phenols using a tyrosinase-based amperometric biosensor detection system
    Adeyoju, O
    Iwuoha, EI
    Smyth, MR
    Leech, D
    [J]. ANALYST, 1996, 121 (12) : 1885 - 1889
  • [2] APHA, 1981, Standard methods for examination of water and waste water, P1134
  • [3] Preparation, characterization and application of alkanethiol self-assembled monolayers modified with tetrathiafulvalene and glucose oxidase at a gold disk electrode
    Campuzano, S
    Gálvez, R
    Pedero, M
    de Villena, FJM
    Pingarrón, JM
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 526 (1-2): : 92 - 100
  • [4] CAMPUZANO S, IN PRESS ANAL BIOANA
  • [5] SELF-ASSEMBLED MONOLAYERS AND ENZYME ELECTRODES - PROGRESS, PROBLEMS AND PROSPECTS
    CREAGER, SE
    OLSEN, KG
    [J]. ANALYTICA CHIMICA ACTA, 1995, 307 (2-3) : 277 - 289
  • [6] Ducey MW, 1998, ELECTROANAL, V10, P157, DOI 10.1002/(SICI)1521-4109(199803)10:3<157::AID-ELAN157>3.0.CO
  • [7] 2-O
  • [8] Self-assembled monolayers: a versatile tool for the formulation of bio-surfaces
    Ferretti, S
    Paynter, S
    Russell, DA
    Sapsford, KE
    Richardson, DJ
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (09) : 530 - 540
  • [9] The application of alkanethiol self-assembled monolayers to enzyme electrodes
    Gooding, JJ
    Hibbert, DB
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (08) : 525 - 533
  • [10] Improved mediated tyrosinase amperometric enzyme electrodes
    Hedenmo, M
    Narvaez, A
    Dominguez, E
    Katakis, I
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 425 (1-2) : 1 - 11