Evaluation of soft-tissue foreign bodies: Comparing conventional plain film radiography, computed radiography printed on film, and computed radiography displayed on a computer workstation

被引:28
作者
Reiner, B [1 ]
Siegel, E [1 ]
McLaurin, T [1 ]
Pomerantz, S [1 ]
Allman, R [1 ]
Hebel, JR [1 ]
Fritz, S [1 ]
Protopapas, Z [1 ]
机构
[1] VET AFFAIRS MED CTR,DEPT RADIOL,BALTIMORE,MD 21201
关键词
D O I
10.2214/ajr.167.1.8659358
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The study was performed to evaluate detection of soft-tissue foreign bodies using conventional radiography (film-screen radiography), computed radiography printed on films (computed radiography-hard copy), and computed radiography displayed on a computer workstation (computed radiography-soft copy). SUBJECTS AND METHODS. Fifteen foreign bodies of different size, shape, and composition were implanted at different locations in a fresh cadaveric hand, and images were obtained using three radiographic techniques. Images were evaluated by four board-certified radiologists to ascertain the conspicuity of the foreign bodies with the different techniques. A subjective grade was assigned to each image in an attempt to identify the relative conspicuity of foreign bodies when imaged with the three techniques. RESULTS. Computed radiography-soft copy is the preferred imaging technique for the detection of wood and plastic foreign bodies in soft tissue regardless of the size of the wood or the plastic, No significant differences in conspicuity among the three techniques were demonstrated with glass foreign bodies. CONCLUSION. Detection of soft-tissue foreign bodies is best done using computed radiography-soft copy instead of film-screen radiography and computed radiography-hard copy imaging.
引用
收藏
页码:141 / 144
页数:4
相关论文
共 22 条
[1]   THE EFFECT OF IRREVERSIBLE IMAGE COMPRESSION ON DIAGNOSTIC-ACCURACY IN THORACIC IMAGING [J].
ABERLE, DR ;
GLEESON, F ;
SAYRE, JW ;
BROWN, K ;
BATRA, P ;
YOUNG, DA ;
STEWART, BK ;
HO, BKT ;
HUANG, HK .
INVESTIGATIVE RADIOLOGY, 1993, 28 (05) :398-403
[2]   DIAGNOSIS AND TREATMENT OF RETAINED FOREIGN-BODIES IN THE HAND [J].
ANDERSON, MA ;
NEWMEYER, WL ;
KILGORE, ES .
AMERICAN JOURNAL OF SURGERY, 1982, 144 (01) :63-67
[3]  
BAUER AR, 1983, ARCH SURG-CHICAGO, V118, P1084
[4]   IMAGING FOREIGN GLASS AND WOODEN BODIES OF THE EXTREMITIES WITH CT AND MR [J].
BODNE, D ;
QUINN, SF ;
COCHRAN, CF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (04) :608-611
[5]  
CAWTHON L A, 1991, Pediatric Emergency Care, V7, P224, DOI 10.1097/00006565-199108000-00007
[6]  
COMBS AH, 1986, ORTHOPEDICS, V9, P1434
[7]  
DONALDSON JS, 1991, HAND CLIN, V7, P125
[8]   SONOGRAPHIC DIAGNOSIS OF FOREIGN-BODIES OF THE DISTAL EXTREMITIES [J].
FORNAGE, BD ;
SCHERNBERG, FL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (03) :567-569
[9]  
FORNAGE BD, 1988, RADIOL CLIN N AM, V26, P109
[10]   HIGH-RESOLUTION COMPUTER DISPLAY OF PORTABLE, DIGITAL, CHEST RADIOGRAPHS OF ADULTS - SUITABILITY FOR PRIMARY INTERPRETATION [J].
FRANK, MS ;
JOST, RG ;
MOLINA, PL ;
ANDERSON, DJ ;
SOLOMON, SL ;
WHITMAN, RA ;
MOORE, SM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :473-477