Spiral versus electron-beam CT for coronary artery calcium scoring

被引:54
作者
Goldin, JG
Yoon, HC
Greaser, LE
Heinze, SB
McNitt-Gray, MM
Brown, MS
Sayre, JW
Emerick, AM
Aberle, DR
机构
[1] Univ Calif Los Angeles, Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Sch Med, Dept Radiol Phys, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Sch Med, Dept Biomath, Los Angeles, CA 90095 USA
[4] Univ Utah, Sch Med, Dept Radiol, Salt Lake City, UT USA
[5] Finch Univ Hlth Sci Chicago Med Sch, N Chicago, IL 60064 USA
关键词
calcium; computed tomography (CT); electron beam; coronary vessels; CT; stenosis or obstruction;
D O I
10.1148/radiol.2211001038
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine differences in coronary artery calcium detection, quantification, and reproducibility, as measured at electron-beam computed tomography (CT) and subsecond spiral CT with retrospective electrocardiogram gating in an asymptomatic adult population. MATERIALS AND METHODS: Seventy subjects asymptomatic for coronary heart disease underwent both electron-beam CT and subsecond spiral CT. In all subjects, two images each were obtained with both scanners. Two experienced readers using three different algorithms scored each of the four scans: one score for the electron-beam CT images and two scores for the spiral CT images. RESULTS: With a 130-HU threshold for the quantification of calcium, there were no significant differences in interscan and interobserver variation in calcium scores between the electron-beam CT and spiral CT images. There was greater interobserver (P < .001) and interscan (P < .03) variation in scores when a 90-HU threshold was used for spiral CT images. With a 130-HU threshold, when calcium scores were used for clinical risk stratification, there was a significant difference between the results obtained with electron-beam CT and those obtained with spiral CT (P < .05). CONCLUSION: Spiral CT has not yet proved to be a feasible alternative to electron-beam CT for coronary artery calcium quantification. There are systematic differences between calcium scores obtained with single-detector array subsecond spiral CT and those obtained with electron-beam CT.
引用
收藏
页码:213 / 221
页数:9
相关论文
共 25 条
[1]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[2]   Predictive value of electron beam computed tomography of the coronary arteries - 19-month follow-up of 1173 asymptomatic subjects [J].
Arad, Y ;
Spadaro, LA ;
Goodman, K ;
LledoPerez, A ;
Sherman, S ;
Lerner, C ;
Guerci, AD .
CIRCULATION, 1996, 93 (11) :1951-1953
[3]   Helical and single-slice conventional CT versus electron beam CT for the quantification of coronary artery calcification [J].
Becker, CR ;
Jakobs, TF ;
Aydemir, S ;
Becker, A ;
Knez, A ;
Schoepf, UJ ;
Bruening, R ;
Haberl, R ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :543-547
[4]  
Bland M., 1987, INTRO MED STAT, P278
[5]   Measurement of coronary artery calcium with dual-slice helical CT compared with coronary angiography: Evaluation of CT scoring methods, interobserver variations, and reproducibility [J].
Broderick, LS ;
Shemesh, J ;
Wilensky, RL ;
Eckert, GJ ;
Zhou, XH ;
Torres, WE ;
Balk, MA ;
Rogers, WJ ;
Conces, DJ ;
Kopecky, KK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) :439-444
[6]   Effect of HMG-Coa reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography [J].
Callister, TQ ;
Raggi, P ;
Cooil, B ;
Lippolis, NJ ;
Russo, DJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1972-1978
[7]   Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method [J].
Callister, TQ ;
Cooil, B ;
Raya, SP ;
Lippolis, NJ ;
Russo, DJ ;
Raggi, P .
RADIOLOGY, 1998, 208 (03) :807-814
[8]   Evaluation of subsecond gated helical CT for quantification of coronary artery calcium and comparison with electron beam CT [J].
Carr, JJ ;
Crouse, JR ;
Goff, DC ;
D'Agostino, RB ;
Peterson, NP ;
Burke, GL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) :915-921
[9]   REPRODUCIBILITY OF THE MEASUREMENT OF CORONARY CALCIUM WITH ULTRAFAST COMPUTED-TOMOGRAPHY [J].
DEVRIES, S ;
WOLFKIEL, C ;
SHAH, V ;
CHOMKA, E ;
RICH, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (14) :973-975
[10]   Detection of coronary artery calcium to differentiate patients with early coronary atherosclerosis from luminally normal arteries [J].
Fallavollita, JA ;
Kumar, K ;
Brody, AS ;
Bunnell, IL ;
Canty, JM .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (11) :1281-&