Determination of carbohydrates by high-performance capillary electrophoresis with indirect absorbance detection

被引:49
作者
Lee, YH
Lin, TI
机构
[1] Department of Chemistry, National Taiwan University
[2] Department of Chemistry, National Taiwan University
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1996年 / 681卷 / 01期
关键词
carbohydrates;
D O I
10.1016/0378-4347(95)00503-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-performance capillary electrophoresis (HPCE) methods with indirect absorbance detection (IAD) have been developed for the determination of carbohydrates, e.g., glucose, fructose, rhamnose, ribose, maltose, lactose, sucrose and gluconic acid. The suitability and performance of six background electrolytes (BGEs), i.e., 1-naphthylacetic acid (NAA), 2-naphthalenesulfonic acid, 1,3-dihydroxynaphthalene, phenylacetic acid, p-cresol and sorbic acid, for the IAD method were investigated. The effects of the concentration of the BGE, pH and temperature on the CE separation of these analytes were evaluated. NAA was found to be best suited as the carrier buffer and background absorbance provider for the detection at 222 nm. The optimal CE performance was found when employing 2 mM NAA, pH 12.2, at 25 degrees C. In comparison with the previous method that used sorbate as the BGE, the present method utilizing NAA shows a 3-6 fold increase in the separation efficiency and a 2-5 fold improvement in the detection limit. The calculated number of theoretical plates is in the range of 1.0-3.0 . 10(5). The precision of the present method for most sugar analytes, measured by the coefficient of variation (C.V.), typically, is less than 1% for the migration time and better than 3% for the peak height and peak area (n=6). The detection limit is about 0.1 mM for all analytes, except for ribose for which it is about 0.2 mM. This new method is fast, accurate and can be readily applied to real biological samples for quantitative determination of selected carbohydrates.
引用
收藏
页码:87 / 97
页数:11
相关论文
共 31 条
[1]   OPTIMIZATION OF INDIRECT UV DETECTION IN CAPILLARY ZONE ELECTROPHORESIS OF LOW-MOLECULAR-MASS ANIONS [J].
BUCHBERGER, W ;
COUSINS, SM ;
HADDAD, PR .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (08) :313-319
[2]   CAPILLARY ZONE ELECTROPHORESIS OF OLIGOSACCHARIDES DERIVATIZED WITH VARIOUS AMINONAPHTHALENE SULFONIC-ACIDS [J].
CHIESA, C ;
ONEILL, RA .
ELECTROPHORESIS, 1994, 15 (8-9) :1132-1140
[3]   RECENT DEVELOPMENTS IN THE CHROMATOGRAPHIC ANALYSIS OF CARBOHYDRATES [J].
CHURMS, SC .
JOURNAL OF CHROMATOGRAPHY, 1990, 500 :555-583
[4]   HIGH-PERFORMANCE ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION OF NUTRITIONALLY SIGNIFICANT CARBOHYDRATES [J].
CORRADINI, C ;
CRISTALLI, A ;
CORRADINI, D .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (16) :3471-3485
[5]  
Dean J.A., 1985, LANGES HDB CHEM, V13
[6]  
GORDON MH, 1990, PRINCIPLES APPL GC F
[7]  
GOULD RF, 1973, CARBOHYDRATE SOLUTIO
[8]   CAPILLARY ZONE ELECTROPHORESIS OF P-AMINOBENZOIC ACID-DERIVATIVES OF ALDOSES, KETOSES AND URONIC-ACIDS [J].
GRILL, E ;
HUBER, C ;
OEFNER, P ;
VORNDRAN, A ;
BONN, G .
ELECTROPHORESIS, 1993, 14 (10) :1004-1010
[9]   CAPILLARY ELECTROPHORESIS SEPARATION OF OLIGOSACCHARIDES .1. EFFECT OF OPERATIONAL VARIABLES [J].
GUTTMAN, A ;
COOKE, N ;
STARR, CM .
ELECTROPHORESIS, 1994, 15 (12) :1518-1522
[10]   INFLUENCE OF BORATE COMPLEXATION ON THE ELECTROPHORETIC BEHAVIOR OF CARBOHYDRATES IN CAPILLARY ELECTROPHORESIS [J].
HOFFSTETTERKUHN, S ;
PAULUS, A ;
GASSMANN, E ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1991, 63 (15) :1541-1547