Real-time spatial compound imaging: Application to breast, vascular, and musculoskeletal ultrasound

被引:171
作者
Entrekin, RR
Porter, BA
Sillesen, HH
Wong, AD
Cooperberg, PL
Fix, CH
机构
[1] ATL Ultrasound Inc, Bothell, WA 98041 USA
[2] First Hill Diagnost Imaging, Seattle, WA USA
[3] Univ Copenhagen, Gentofte Hosp, Dept Vasc Surg, Hellerup, Denmark
[4] Univ British Columbia, St Pauls Hosp, Dept Radiol, Vancouver, BC V5Z 1M9, Canada
关键词
D O I
10.1016/S0887-2171(01)90018-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Real-time spatial compound imaging (SonoCT) is an ultrasound technique that uses electronic beam steering of a transducer array to rapidly acquire several (three to nine) overlapping scans of an object from different view angles. These single-angle scans are averaged to form a multiangle compound image that is updated in real time with each subsequent scan. Compound imaging shows improved image quality compared with conventional ultrasound, primarily because of reduction of speckle, clutter, and other acoustic artifacts. Early clinical experience suggests that real-time spatial compound imaging can provide improved contrast resolution and tissue differentiation that is beneficial for imaging the breast, peripheral blood vessels, and musculoskeletal injuries. Future development of real-time spatial compound imaging will help address the bulk of general imaging applications by extending this technology to curved array transducers, tissue harmonics, panoramic imaging, and three-dimensional sonography. © 2001 by W.B. Saunders Company.
引用
收藏
页码:50 / 64
页数:15
相关论文
共 42 条
[1]   Extended field-of-view sonography in musculoskeletal disorders [J].
Barberie, JE ;
Wong, AD ;
Cooperberg, PL ;
Carson, BW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (03) :751-757
[2]  
BERSON M, 1988, ULTRASONIC IMAGING, V3, P303
[3]   Incidental findings on sonography of the breast:: Clinical significance and diagnostic workup [J].
Buchberger, W ;
DeKoekkoek-Doll, P ;
Springer, P ;
Obrist, P ;
Dünser, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (04) :921-927
[4]   SPECKLE IN ULTRASOUND B-MODE SCANS [J].
BURCKHARDT, CB .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (01) :1-6
[5]   Nonlinear imaging [J].
Burns, PN ;
Simpson, DH ;
Averkiou, MA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 :S19-S22
[6]   Sonographic evaluation of infiltrating lobular carcinoma [J].
Butler, RS ;
Venta, LA ;
Wiley, EL ;
Ellis, RL ;
Dempsey, PJ ;
Rubin, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (02) :325-330
[7]   UI OCTOSON - NEW CLASS OF ULTRASONIC ECHOSCOPE [J].
CARPENTER, D ;
KOSSOFF, G ;
GARRETT, WJ ;
DANIEL, K ;
BOELE, P .
AUSTRALASIAN RADIOLOGY, 1977, 21 (01) :85-89
[8]   A MULTIMODE REAL-TIME SCANNER [J].
CARPENTER, DA ;
DADD, MJ ;
KOSSOFF, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1980, 6 (03) :279-284
[9]   CAROTID-ARTERY DUPLEX SCANNING - DOES PLAQUE ECHOGENICITY CORRELATE WITH PATIENT SYMPTOMS [J].
CAVE, EM ;
PUGH, ND ;
WILSON, RJ ;
SISSONS, GRJ ;
WOODCOCK, JP .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1995, 10 (01) :77-81
[10]   GRAY SCALE ULTRASOUND IN EVALUATION OF RHEUMATOID-ARTHRITIS OF KNEE [J].
COOPERBERG, PL ;
TSANG, I ;
TRUELOVE, L ;
KNICKERBOCKER, J .
RADIOLOGY, 1978, 126 (03) :759-763