Carbon Dioxide Capture from Flue Gases Using a Cross-Flow Membrane Contactor and the Ionic Liquid 1-Ethyl-3-methylimidazolium Ethylsulfate

被引:162
作者
Albo, Jonathan [1 ]
Luis, Patricia [1 ]
Irabien, Angel [1 ]
机构
[1] Univ Cantabria, ES-39005 Santander, Spain
关键词
MASS-TRANSFER; PROCESS INTENSIFICATION; CO2; ABSORPTION; MODULES;
D O I
10.1021/ie1014266
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Carbon dioxide (CO2) emissions have to be controlled and reduced in order to avoid environmental risks. Membrane processes in combination with the use of ionic liquids are recently under research and development in order to demonstrate a zero solvent emission process for CO2 capture. In this work, the application of a cross-flow membrane contactor is studied for CO2 absorption when the ionic liquid 1-ethyl-3-methylimidazolium ethylsulfate is used as solvent. A mathematical model considering a parallel flow configuration is applied for a cross-flow system in order to describe the mass transfer rate. At a macroscopic level, K(overall)a is calculated considering different mixing models corresponding to plug flow and continuous stirred models and a first order mass transfer rate. A microscopic model based on laminar flow has been applied, obtaining a membrane mass transfer coefficient of k(m) = 3.78 x 10(-6) m.s(-1) which is about five times higher than that obtained in the macroscopic model. The interfacial area, a, allows the comparison of efficiencies between cross-flow and parallel membrane contactor systems in terms of the product (K(overall)a).
引用
收藏
页码:11045 / 11051
页数:7
相关论文
共 28 条
[1]   Modeling of CO2 absorption in membrane contactors [J].
Al-Marzouqi, Mohamed H. ;
El-Naas, Muftah H. ;
Marzouk, Sayed A. M. ;
Al-Zarooni, Mohamed A. ;
Abdullatif, Nadia ;
Faiz, Rami .
SEPARATION AND PURIFICATION TECHNOLOGY, 2008, 59 (03) :286-293
[2]  
ALBO J, DESALINATION UNPUB
[3]  
Bhaumik S, 1998, J MEMBRANE SCI, V138, P77
[4]  
Bird R B., 2002, Transportphenomena
[5]   Membrane distillation and related operations - A review [J].
Curcio, E ;
Drioli, E .
SEPARATION AND PURIFICATION REVIEWS, 2005, 34 (01) :35-86
[6]   Comparing the absorption performance of packed columns and membrane contactors [J].
deMontigny, D ;
Tontiwachwuthikul, P ;
Chakma, A .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (15) :5726-5732
[7]   Modelling of cross-flow membrane contactors: physical mass transfer processes [J].
Dindore, VY ;
Brilman, DWF ;
Versteeg, GF .
JOURNAL OF MEMBRANE SCIENCE, 2005, 251 (1-2) :209-222
[8]   Gas-liquid mass transfer in a cross-flow hollow fiber module: Analytical model and experimental validation [J].
Dindore, VY ;
Versteeg, GF .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (16) :3352-3362
[9]   State of the art and recent progresses in membrane contactors [J].
Drioli, E ;
Curcio, E ;
Di Profio, G .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2005, 83 (A3) :223-233
[10]   Membrane engineering for process intensification: a perspective [J].
Drioli, Enrico ;
Curcio, Efrem .
JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2007, 82 (03) :223-227