EEG-based neuroprosthesis control:: A step towards clinical practice

被引:302
作者
Müller-Putz, GR
Scherer, R
Pfurtscheller, G
Rupp, R
机构
[1] Graz Univ Technol, Inst Comp Graphics & Vis, Lab Brain Comp Interfaces, A-8010 Graz, Austria
[2] Ludwig Boltzmann Inst Med Informat & Neuroinforma, A-8010 Graz, Austria
[3] Univ Heidelberg, Orthoped Hosp, Dept 2, D-69118 Heidelberg, Germany
关键词
brain-computer interface (BCI); neuroprosthesis; hand grasp restoration; spinal cord injury (SCI); tetraplegia;
D O I
10.1016/j.neulet.2005.03.021
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This case study demonstrates the coupling of an electroencephalogram (EEG)-based Brain-Computer Interface (BCI) with an implanted neuroprosthesis (Freehand((R)) system). Because the patient was available for only 3 days, the goal was to demonstrate the possibility of a patient gaining control over the motor imagery-based Graz BCI system within a very short training period. By applying himself to an organized and coordinated training procedure, the patient was able to generate distinctive EEG-patterns by the imagination of movements of his paralyzed left hand. These patterns consisted of power decreases in specific frequency bands that could be classified by the BCI. The Output signal of the BCI emulated the shoulder joystick usually used, and by consecutive imaginations the patient was able to switch between different grasp phases of the lateral grasp that the Freehand((R)) system provided. By performing a part of the grasp-release test, the patient was able to move a simple object from one place to another. The results presented in this work give evidence that Brain-Computer Interfaces are an option for the control of neuroprostheses in patients with high spinal cord lesions. The fact that the user learned to control the BCI in a comparatively short time indicates that this method may also be an alternative approach for clinical purposes. (c) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 21 条
  • [1] [Anonymous], [No title captured]
  • [2] A spelling device for the paralysed
    Birbaumer, N
    Ghanayim, N
    Hinterberger, T
    Iversen, I
    Kotchoubey, B
    Kübler, A
    Perelmouter, J
    Taub, E
    Flor, H
    [J]. NATURE, 1999, 398 (6725) : 297 - 298
  • [3] Electrically stimulated elbow extension in persons with C5/C6 tetraplegia: A functional and physiological evaluation
    Bryden, AM
    Memberg, WD
    Crago, PE
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2000, 81 (01): : 80 - 88
  • [4] Visualization of significant ERD/ERS patterns in multichannel EEG and ECoG data
    Graimann, B
    Huggins, JE
    Levine, SP
    Pfurtscheller, G
    [J]. CLINICAL NEUROPHYSIOLOGY, 2002, 113 (01) : 43 - 47
  • [5] Control of a hand grasp neuroprosthesis using an electroencephalogram-triggered switch: demonstration of improvements in performance using wavepacket analysis
    Heasman, JM
    Scott, TRD
    Kirkup, L
    Flynn, RY
    Vare, VA
    Gschwind, CR
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2002, 40 (05) : 588 - 593
  • [6] KAUHANEN L, 2004, P 2 INT BRAIN COMP I, V49, P59
  • [7] IMPLANTABLE FUNCTIONAL NEUROMUSCULAR STIMULATION IN THE TETRAPLEGIC HAND
    KEITH, MW
    PECKHAM, PH
    THROPE, GB
    STROH, KC
    SMITH, B
    BUCKETT, JR
    KILGORE, KL
    JATICH, JW
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1989, 14A (03): : 524 - 530
  • [8] Critical decision-speed and information transfer in the "Graz Brain-Computer Interface"
    Krausz, G
    Scherer, R
    Korisek, G
    Pfurtscheller, G
    [J]. APPLIED PSYCHOPHYSIOLOGY AND BIOFEEDBACK, 2003, 28 (03) : 233 - 240
  • [9] EEG-based control of a hand grasp neuroprosthesis
    Lauer, RT
    Peckham, PH
    Kilgore, KL
    [J]. NEUROREPORT, 1999, 10 (08) : 1767 - 1771
  • [10] Applications of cortical signals to neuroprosthetic control: A critical review
    Lauer, RT
    Peckham, PH
    Kilgore, KL
    Heetderks, WJ
    [J]. IEEE TRANSACTIONS ON REHABILITATION ENGINEERING, 2000, 8 (02): : 205 - 208