A neural network model to predict lung radiation-induced pneumonitis

被引:50
作者
Chen, Shifeng [1 ]
Zhou, Sumin [1 ]
Zhang, Junan [1 ]
Yin, Fang-Fang [1 ]
Marks, Lawrence B. [1 ]
Das, Shiva K. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
关键词
feed-forward neural network; back-propagation; radiation pneumonitis; modeling; prediction;
D O I
10.1118/1.2759601
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
A feed-forward neural network was investigated to predict the occurrence of lung radiation-induced Grade 2+ pneumonitis. The database consisted of 235 patients with lung cancer treated using radiotherapy, of whom 34 were diagnosed with Grade 2+ pneumonitis at follow-up. The network was constructed using an algorithm that alternately grew and pruned it, starting from the smallest possible network, until a satisfactory solution was found. The weights and biases of the network were computed using the error back-propagation approach. Momentum and variable leaning techniques were used,to speed convergence. Using the growing/pruning approach, the network selected features from 66 dose and 27 non-dose variables. During network training, the 235 patients were randomly split into ten groups of approximately equal size. Eight groups were used to train the network, one group was used for early stopping training to prevent overfitting, and the remaining group was used as a test to measure the generalization capability of the network (cross-validation). Using this methodology, each of the ten groups was considered, in turn, as the test group (ten-fold cross-validation). For the optimized network constructed with input features selected from dose and non-dose variables, the area under the receiver operating characteristics (ROC) curve for cross-validated testing was 0.76 (sensitivity: 0.68, specificity: 0.69). For the optimized network constructed with input features selected only from dose variables, the area under the ROC curve for cross-validation was 0.67 (sensitivity: 0.53, specificity: 0.69). The difference between these two areas was statistically significant (p=0.020), indicating that the addition of non-dose features can significantly improve the generalization capability of the network. A network for prospective testing was constructed with input features selected from dose and non-dose variables (all data were used for training). The optimized network architecture consisted of six input nodes (features), four hidden nodes, and one output node. The six input features were: lung volume receiving >16 Gy (V-16), generalized equivalent uniform dose (gEUD) for the exponent a= I (mean lung dose), gEUD for the exponent a= 3.5, free expiratory volume in, 1 s (FEV1), diffusion capacity of carbon monoxide (DLCO%), and whether or not the patient underwent chemotherapy prior to radiotherapy. The significance of each input feature was individually evaluated by omitting it during network training and gauging its impact by the consequent deterioration in cross-validated ROC area. With the , exception of FEV1 and whether or not the patient underwent chemotherapy prior to radiotherapy, all input features were found to be individually significant (p < 0.05). The network for prospective testing is publicly available via internet access. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:3420 / 3427
页数:8
相关论文
共 43 条
[1]
[Anonymous], RAD RES S
[2]
Radiotherapy and concurrent continuous infusion of cisplatin with adjuvant surgery in nonresectable Stage III lung carcinoma: Short- and long-term results of a Phase II study [J].
Bedini, AV ;
Tavecchio, L ;
Gramaglia, A ;
Villa, S ;
Palazzi, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (03) :613-621
[3]
Response, toxicity, failure patterns, and survival in five radiation therapy oncology group (RTOG) trials of sequential and/or concurrent chemotherapy and radiotherapy for locally advanced non-small-cell carcinoma of the lung [J].
Byhardt, RW ;
Scott, C ;
Sause, WT ;
Emami, B ;
Komaki, R ;
Fisher, B ;
Lee, JS ;
Lawton, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03) :469-478
[4]
The impact of heterogeneity correction on dosimetric parameters that predict for radiation pneumonitis [J].
Chang, Daniel T. ;
Olivier, Kenneth R. ;
Morris, Christopher G. ;
Liu, Chihray ;
Dempsey, James F. ;
Benda, Rashmi K. ;
Palta, Jatinder R. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (01) :125-131
[5]
Hyperfractionated accelerated radiation therapy for nonsmall cell lung cancer: Clinical phase I/II trial [J].
Fu, XL ;
Jiang, GL ;
Wang, LJ ;
Qian, H ;
Fu, S ;
Yie, M ;
Kong, FM ;
Zhao, S ;
He, SQ ;
Liu, TF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (03) :545-552
[6]
Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC) [J].
Graham, MV ;
Purdy, JA ;
Emami, B ;
Harms, W ;
Bosch, W ;
Lockett, MA ;
Perez, CA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02) :323-329
[7]
Preliminary results of a prospective trial using three dimensional radiotherapy for lung cancer [J].
Graham, MV ;
Purdy, JA ;
Emami, B ;
Matthews, JW ;
Harms, WB .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :993-1000
[8]
Hastie T., 2002, ELEMENTS STAT LEARNI
[9]
Radiation-induced pulmonary toxicity: A dose-volume histogram analysis in 201 patients with lung cancer [J].
Hernando, ML ;
Marks, LB ;
Bentel, GC ;
Zhou, SM ;
Hollis, D ;
Das, SK ;
Fan, M ;
Munley, MT ;
Shafman, TD ;
Anscher, MS ;
Lind, PA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (03) :650-659
[10]
Modeling radiation pneumonitis risk with clinical, dosimetric, and spatial parameters [J].
Hope, Andrew J. ;
Lindsay, Patricia E. ;
El Naqa, Issam ;
Alaly, James R. ;
Vicic, Milos ;
Bradley, Jeffrey D. ;
Deasy, Joseph O. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (01) :112-124