Comparison of spontaneous frontal EMG, EEG power spectrum and bispectral index to monitor propofol drug effect and emergence

被引:57
作者
Struys, M
Versichelen, L
Mortier, E
Ryckaert, D
De Mey, JC
De Deyne, C
Rolly, G
机构
[1] State Univ Ghent Hosp, Dept Anaesthesia, B-9000 Ghent, Belgium
[2] Ziekenhuis Oost Limburg, Gent, Belgium
关键词
bispectral index; electroencephalography; frontal electromyography; propofol; spectral edge;
D O I
10.1111/j.1399-6576.1998.tb05293.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The aim of this study was to investigate the accuracy of frontal spontaneous electromyography (SEMG) and EEG spectral edge frequency (SEF 95%), median frequency (MF), relative delta power (RDELTA) and bispectral index (BIS) in monitoring loss of and return of consciousness and hypnotic drug effect during propofol administration at different calculated plasma target concentrations. Methods: Propofol was administered by using a target-controlled infusion at different propofol steady-state concentrations. All variables were measured simultaneously at specific calculated concentrations and endpoints. Results: Loss of consciousness was accurately monitored by BIS, SEMG and SEF 95%, and propofol drug effect by BIS only Return of consciousness was predicted by BIS, MF and SEF 95%. Due to the biphasic EEG pattern of propofol and the lack of reproducible data at specific propofol concentrations, the clinical usefulness of SEF 95%, MF and RDELTA was very Limited. SEMG was useful to detect loss and return of consciousness, but without predictive value. Conclusions: The BIS might be an accurate measure to monitor depth of anaesthesia and hypnotic drug effect. Other neurophysiologic measures have limited value to monitor depth of anaesthesia and hypnotic drug effect. (C) Acta Anaesthesiologica Scandinavica 42 (1998).
引用
收藏
页码:628 / 636
页数:9
相关论文
共 36 条
[1]  
[Anonymous], ANAES PHARM REV
[2]   EXAGGERATED ANESTHETIC REQUIREMENTS IN THE PREFERENTIALLY ANESTHETIZED BRAIN [J].
ANTOGNINI, JF ;
SCHWARTZ, K .
ANESTHESIOLOGY, 1993, 79 (06) :1244-1249
[3]   A comparison of spectral edge, delta power, and bispectral index as EEG measures of alfentanil, propofol, and midazolam drug effect [J].
Billard, V ;
Gambus, PL ;
Chamoun, N ;
Stanski, DR ;
Shafer, SL .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1997, 61 (01) :45-58
[4]  
CHANG TL, 1988, ANESTH ANALG, V67, P521
[5]  
CHERNIK DA, 1990, J CLIN PSYCHOPHARM, V10, P244
[6]   PHARMACOKINETIC MODEL SELECTION FOR TARGET CONTROLLED INFUSIONS OF PROPOFOL - ASSESSMENT OF 3 PARAMETER SETS [J].
COETZEE, JF ;
GLEN, JB ;
WIUM, CA ;
BOSHOFF, L .
ANESTHESIOLOGY, 1995, 82 (06) :1328-1345
[7]   EFFECTIVE CONCENTRATION 50 FOR PROPOFOL WITH AND WITHOUT 67-PERCENT NITROUS-OXIDE [J].
DAVIDSON, JAH ;
MACLEOD, AD ;
HOWIE, JC ;
WHITE, M ;
KENNY, GNC .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1993, 37 (05) :458-464
[8]   Relationship between calculated blood concentration of propofol and electrophysiological variables during emergence from anaesthesia: Comparison of bispectral index, spectral edge frequency, median frequency and auditory evoked potential index [J].
Doi, M ;
Gajraj, RJ ;
Mantzaridis, H ;
Kenny, GNC .
BRITISH JOURNAL OF ANAESTHESIA, 1997, 78 (02) :180-184
[9]   THE ELECTROENCEPHALOGRAM DOES NOT PREDICT DEPTH OF ISOFLURANE ANESTHESIA [J].
DWYER, RC ;
RAMPIL, IJ ;
EGER, EI ;
BENNETT, HL .
ANESTHESIOLOGY, 1994, 81 (02) :403-409
[10]  
EDMONDS HL, 1993, ACTA ANAESTHESI S100, V37, P102