Enhancement of a culture-based bacterial detection system (eBDS) for platelet products based on measurement of oxygen consumption

被引:30
作者
Holme, S
McAlister, MB
Ortolano, GA
Chong, C
Cortus, MA
Jacobs, MR
Yomtovian, R
Freundlich, LF
Wenz, B
机构
[1] Pall Corp, Pall Med, Sci Affairs, E Hills, NY 11548 USA
[2] Case Western Reserve Univ, Cleveland, OH 44106 USA
[3] Univ Hosp Cleveland, Cleveland, OH 44106 USA
关键词
D O I
10.1111/j.1537-2995.2005.04405.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: An enhanced bacterial detection system (Pall eBDS) was developed that distinguishes itself from its predecessor (Pall BDS) by removal of the platelet (PLT)-retaining filter allowing for optimal bacterial transfer, modification of the culture tablet to reduce the confounding effects of respiring PLTs while enhancing bacterial growth, and facilitation of nutrients and gas exchange by agitating the sample pouch during incubation at 35 degrees C. The objective was to evaluate the performance of the new eBDS. Study Design and Methods: Leukoreduced whole blood-derived PLT concentrates (LR-PCs) and LR single-donor PLTs (LR-SDPs) were inoculated with 1 to 15 colony-forming units (CFUs) of bacteria per mL in studies of each of 10 bacterial species associated with fatal transfusion-transmitted bacterial infection. Immediately after inoculation and after 24 hours of storage at 22 degrees C, samples of inoculated LR-PCs were aseptically transferred into the eBDS pouches. Pouches were then incubated for 24 hours at 35 degrees C with agitation and oxygen concentration was then measured. Results: Median inoculation levels ranged from 5 to 13 CFUs per mL for each species studied. No significant differences in oxygen concentration were found when comparing LR-PCs with LR-SDPs. When sampling occurred from the PLTs 24 hours after inoculation, all 280 cases (24-33 replicates of each species) were detected as contaminated by the device (100% sensitivity). No false-positives were obtained with 713 uninoculated PLT units. Conclusions: The eBDS demonstrated improved detection sensitivity in the range of 1 to 15 CFUs per mL with no observed false-positives compared to the original BDS (detection range 100 to 500 CFUs/mL) with no false-positives.
引用
收藏
页码:984 / 993
页数:10
相关论文
共 21 条
[1]   Bacterial contamination of cellular blood components: risks, sources and control [J].
Blajchman, MA .
VOX SANGUINIS, 2004, 87 :98-103
[2]  
Brecher Mark E, 2004, Curr Hematol Rep, V3, P121
[3]  
Burns KH, 2004, ARCH PATHOL LAB MED, V128, P279
[4]   Bacterial contamination of blood products: Factors, options, and insights [J].
Depcik-Smith, ND ;
Hay, SN ;
Brecher, ME .
JOURNAL OF CLINICAL APHERESIS, 2001, 16 (04) :192-201
[5]  
DODD R, 2003, ASS B AM ASS BLOOD B, V312
[6]  
DODD R, 2003, ASS B AM ASS BLOOD B, V307
[7]   Validation of pH and glucose determination for bacteria detection screening in platelet concentrates stored in the Terumo Teruflex XT612 platelet container [J].
Hay, SN ;
Brecher, ME .
TRANSFUSION, 2004, 44 (09) :1395-1395
[8]  
Hillyer Christopher D, 2003, Hematology Am Soc Hematol Educ Program, P575
[9]  
LEE JH, 1999, WORKSH BACT CONT PLA
[10]  
McDonald CP, 1998, TRANSFUSION MED, V8, P19