Long-term study of high-strength hydroxyapatite/poly(L-lactide) composite rods for the internal fixation of bone fractures: A 2-4-year follow-up study in rabbits

被引:43
作者
Ishii, S
Tamura, J
Furukawa, T
Nakamura, T
Matsusue, Y
Shikinami, Y
Okuno, M
机构
[1] Kyoto Univ, Grad Sch Med, Dept Orthopaed Surg, Sakyo Ku, Kyoto 6068507, Japan
[2] Shiga Univ Med Sci, Dept Orthopaed Surg, Shiga 5202192, Japan
[3] Takiron Co Ltd, Shisou Gun, Hyogo 6712421, Japan
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS | 2003年 / 66B卷 / 02期
关键词
composites; poly(L-lactide); hydroxyapatite; internal fixation; long-term animal study;
D O I
10.1002/jbm.b.10027
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Biodegradation of hydroxyapatite (HA)/poly(L-lactide)(PLLA) composite bone implant rods was studied with the use of two types of HA particles as reinforcing fillers: uncalcined HA (u-HA) or calcined HA (c-HA). Composite rods of u-HA/PLLA and c-HA/ PLLA containing 30 or 40% (w/w) HA were implanted in the distal femur of 21 rabbits, and specimens were examined by light microscopy, scanning-electron microscopy (SEM), and transmission-electron microscopy (TEM) 2-4 years later. For u-HA/PLLA, trabecular bone bonding directly onto the rod was maintained for up to 2 years. By 3 years, surface collapse had begun, and the implants were shrinking. By 4 years, they had shrunk further, with complete bone encapsulation. The u-HA particles were small and needle shaped in the peripheries, and TEM confirmed their resorption. The cross-sectional area after 4 years decreased by 23.3 +/- 8.4%. The mean ratio of bony ingrowth to the initial cross-sectional area around the shrunken rods was 6.7 +/- 1.3 %. The viscosity molecular weight of PLLA reduced from 2 x 10(5) to less than 1 x 10(3). Thus, most of the PLLA had released from the rods. The c-HA/PLLA implants also showed good osteoconductivity, but shrinkage and infiltration of histiocytes were less. No osteolytic or osteoarthritic changes were found. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:539 / 547
页数:9
相关论文
共 38 条
[1]
ACUNA V, 1992, ADV BIOMAT, V10, P391
[2]
BIODEGRADABLE FIXATION OF ANKLE FRACTURES - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY OF 32 CASES [J].
AHL, T ;
DALEN, N ;
LUNDBERG, A ;
WYKMAN, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (02) :166-170
[3]
FOREIGN-BODY REACTIONS TO RESORBABLE POLY(L-LACTIDE) BONE PLATES AND SCREWS USED FOR THE FIXATION OF UNSTABLE ZYGOMATIC FRACTURES [J].
BERGSMA, EJ ;
ROZEMA, FR ;
BOS, RRM ;
DEBRUIJN, WC .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (06) :666-670
[4]
BLOEBAUM RD, 1994, CLIN ORTHOP RELAT R, P19
[5]
HYDROXYAPATITE REINFORCED POLYETHYLENE - A MECHANICALLY COMPATIBLE IMPLANT MATERIAL FOR BONE-REPLACEMENT [J].
BONFIELD, W ;
GRYNPAS, MD ;
TULLY, AE ;
BOWMAN, J ;
ABRAM, J .
BIOMATERIALS, 1981, 2 (03) :185-186
[6]
ANKLE FRACTURES TREATED USING BIODEGRADABLE INTERNAL-FIXATION [J].
BOSTMAN, O ;
HIRVENSALO, E ;
VAINIONPAA, S ;
MAKELA, A ;
VIHTONEN, K ;
TORMALA, P ;
ROKKANEN, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (238) :195-203
[7]
Osteoarthritis of the ankle after foreign-body reaction to absorbable pins and screws -: A three- to nine-year follow-up study [J].
Böstman, OM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :333-338
[8]
Three-dimensional degradable porous polymer-ceramic matrices for use in bone repair [J].
Devin, JE ;
Attawia, MA ;
Laurencin, CT .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1996, 7 (08) :661-669
[9]
BIODEGRADABLE FIXATION OF PHYSEAL FRACTURES IN GOAT DISTAL FEMUR [J].
DONIGIAN, AM ;
PLAGA, BR ;
CASKEY, PM .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1993, 13 (03) :349-354
[10]
INVITRO AND INVIVO EVALUATION OF POLYHYDROXYBUTYRATE AND OF POLYHYDROXYBUTYRATE REINFORCED WITH HYDROXYAPATITE [J].
DOYLE, C ;
TANNER, ET ;
BONFIELD, W .
BIOMATERIALS, 1991, 12 (09) :841-847