Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months

被引:54
作者
Letsou, GV
Myers, TJ
Gregoric, ID
Delgado, R
Shah, N
Robertson, K
Radovancevic, B
Frazier, OH
机构
[1] Univ Texas, Sch Med, Dept Cardiothorac & Vasc Surg, Houston, TX 77030 USA
[2] St Lukes Episcopal Hosp, Texas Heart Inst, Houston, TX USA
关键词
D O I
10.1016/S0003-4975(03)00724-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The Jarvik 2000 axial flow left ventricular assist device (LVAD), under development for the past decade, has the potential to support patients temporarily until cardiac transplantation or as a permanent circulatory support, without the size limitations of other implantable systems. Methods. To assess its ability to perfuse the kidneys and liver, we monitored renal and hepatic function in 10 patients who received the Jarvik 2000 LVAD as a bridge to transplantation. Left ventricular assistance was maintained for up to 214 days (> 6 months), and renal and hepatic function were monitored at least weekly. Results. Renal function before LVAD implantation in these patients was normal in 7 (creatinine, < 1.5) and moderately impaired in 3 (creatinine, 1.2 to 2.0). Hepatic function was normal in 7 patients before LVAD implantation (total bilirubin < 1.2; serum glutamic-oxaloacetic transaminase (SGOT), < 40; serum glutamic-pyruvic transaminase (SGPT), < 50) and normal at the time of transplantation in all 10 patients. Of the 3 patients with abnormal hepatic function before LVAD implantation, 1 patient had also had moderate renal dysfunction. Conclusions. Despite reduced pulsatility, the Jarvik 2000 LVAD improves or maintains excellent renal and hepatic function during periods of circulatory assistance in patients awaiting transplantation. (C) 2003 by The Society of Thoracic Surgeons.
引用
收藏
页码:1167 / 1170
页数:4
相关论文
共 10 条
  • [1] Frazier O H., 2001, J Heart Lung Transplant, V20, P201
  • [2] Research and development of an implantable, axial-flow left ventricular assist device: The Jarvik 2000 heart
    Frazier, OH
    Myers, TJ
    Jarvik, RK
    Westaby, S
    Pigott, DW
    Gregoric, ID
    Khan, T
    Tamez, DW
    Conger, JL
    Macris, MP
    [J]. ANNALS OF THORACIC SURGERY, 2001, 71 (03) : S125 - S132
  • [3] Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system
    Frazier, OH
    Myers, TJ
    Gregoric, ID
    Khan, T
    Delgado, R
    Croitoru, M
    Miller, K
    Jarvik, R
    Westaby, S
    [J]. CIRCULATION, 2002, 105 (24) : 2855 - 2860
  • [4] Evolution of battery powered, vented left ventricular assist devices
    Frazier, OH
    [J]. ANNALS OF THORACIC SURGERY, 1996, 61 (01) : 393 - 395
  • [5] Hepatic dysfunction after left ventricular mechanical assist in patients with end-stage heart failure: Role of inflammatory response and hepatic microcirculation
    Masai, T
    Sawa, Y
    Ohtake, S
    Nishida, T
    Nishimura, M
    Fukushima, N
    Yamaguchi, T
    Matsuda, H
    [J]. ANNALS OF THORACIC SURGERY, 2002, 73 (02) : 549 - 555
  • [6] One hundred patients with the HeartMate left ventricular assist device: Evolving concepts and technology
    McCarthy, PM
    Smedira, NO
    Vargo, RL
    Goormastic, M
    Hobbs, RE
    Starling, RC
    Young, JB
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (04) : 904 - 912
  • [7] HEMODYNAMIC AND PHYSIOLOGICAL-CHANGES DURING SUPPORT WITH AN IMPLANTABLE LEFT-VENTRICULAR ASSIST DEVICE
    MCCARTHY, PM
    SAVAGE, RM
    FRASER, CD
    VARGO, R
    JAMES, KB
    GOORMASTIC, M
    HOBBS, RE
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 109 (03) : 409 - 418
  • [8] MYERS TJ, 2000, J HEART FAILURE CIRC, V3, P133
  • [9] Improved outcomes with an implantable left ventricular assist system: A multicenter study
    Portner, PM
    Jansen, PGM
    Oyer, PE
    Wheeldon, DR
    Ramasamy, N
    [J]. ANNALS OF THORACIC SURGERY, 2001, 71 (01) : 205 - 209
  • [10] Implant technique for the Jarvik 2000 Heart
    Westaby, S
    Frazier, OH
    Pigott, DW
    Saito, S
    Jarvik, RK
    [J]. ANNALS OF THORACIC SURGERY, 2002, 73 (04) : 1337 - 1340