Application of compact porous disks for fast separations of biopolymers and in-process control in biotechnology

被引:93
作者
Strancar, A
Koselj, P
Schwinn, H
Josic, D
机构
[1] OCTAPHARMA PHARMAZEUT PROD GESMBH,A-1100 VIENNA,AUSTRIA
[2] BIA DOO,LJUBLJANA 1000,SLOVENIA
关键词
D O I
10.1021/ac960292f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Production and downstream processing in biotechnology requires fast and accurate control of each step in the process, Improved techniques which can be validated are required in order to meet these demands. For these purposes, chromatographic units containing compact porous disks for fast separation of biopolymers were developed and investigated with regard to their performance and speed, The problems that have, in the past, arisen from the use of wide and flat separation units, such as membranes and disks, have chiefly been those of sample distribution and large void volumes before and behind the unit. Improvements in the construction of the cartridge have led to better performance of the compact porous disks and faster separation, Using these disks, three calibration standard proteins could be separated within less than 1 min by an anion-exchange, cation-exchange, and hydrophobic interaction mode, Such units can be used for in-process control in production and downstream processing of biopolymers, as was shown in experiments involving the purification of al-antitrypsin and clotting factor IX and the immobilization of enzyme glucose oxidase on an epoxy-activated compact porous disk.
引用
收藏
页码:3483 / 3488
页数:6
相关论文
共 38 条
[1]   CARRIER MEMBRANE AS A STATIONARY PHASE FOR AFFINITY-CHROMATOGRAPHY AND KINETIC-STUDIES OF MEMBRANE-BOUND ENZYMES [J].
ABOUREBYEH, H ;
KORBER, F ;
SCHUBERTREHBERG, K ;
REUSCH, J ;
JOSIC, D .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 566 (02) :341-350
[2]  
AFEYAN NB, 1991, LC GC-MAG SEP SCI, V9, P824
[3]  
BELENKII BG, 1995, BIOTECHNIQUES, V18, P288
[4]   RAPID PROTEIN PROFILING WITH A NOVEL ANION-EXCHANGE MATERIAL [J].
BURKE, DJ ;
DUNCAN, JK ;
DUNN, LC ;
CUMMINGS, L ;
SIEBERT, CJ ;
OTT, GS .
JOURNAL OF CHROMATOGRAPHY, 1986, 353 :425-437
[5]  
CSEN H, 1995, J CHROMATOGR A, V705, P3
[6]  
DONG M W, 1989, Biochromatography, V4, P19
[7]   VERY HIGH-SPEED SEPARATION OF PROTEINS WITH A 20-MU-M REVERSED-PHASE SORBENT [J].
FULTON, SP ;
AFEYAN, NB ;
GORDON, NF ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1991, 547 (1-2) :452-456
[8]  
GAGANON P, 1995, BIOPHARM, V8, P21
[9]   A FLOW-INJECTION ANALYSIS SYSTEM FOR FERMENTATION MONITORING AND CONTROL [J].
GARN, M ;
GISIN, M ;
THOMMEN, C ;
CEVEY, P .
BIOTECHNOLOGY AND BIOENGINEERING, 1989, 34 (04) :423-428
[10]   MEMBRANE CHROMATOGRAPHIC SYSTEMS FOR HIGH-THROUGHPUT PROTEIN SEPARATIONS [J].
GERSTNER, JA ;
HAMILTON, R ;
CRAMER, SM .
JOURNAL OF CHROMATOGRAPHY, 1992, 596 (02) :173-180