Planning for camera-guided robotic radiosurgery

被引:31
作者
Schweikard, A [1 ]
Bodduluri, M
Adler, JR
机构
[1] Tech Univ Munich, Dept Comp Sci, D-81667 Munich, Germany
[2] Accuray Inc, Sunnyvale, CA 94086 USA
[3] Stanford Univ, Dept Neurosurg, Stanford, CA 94305 USA
来源
IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION | 1998年 / 14卷 / 06期
关键词
collision avoidance; geometric reasoning; image-guided surgery; medical physics; medical robotics; motion planning; radiation therapy; radiosurgery; treatment planning;
D O I
10.1109/70.736778
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Radiosurgery is a treatment for brain tumors and other lesions which employs a moving beam of photon radiation. In robotic radiosurgery, the radiation source is moved by a six degree-of-freedom robotic arm. A treatment planning system for robotic radiosurgery was developed. This planning system combines collision avoidance techniques and geometric algorithms for finding appropriate robot paths and beam activation profiles, The following design goals characterize our application: 1) ability to generate conformal three-dimensional (3-D) dose distributions; 2) transparency of the planning process; 3) full use of the motion flexibility provided by the robotic arm. The new planning system is in clinical use in several leading medical institutions. Results obtained from studies suggest that highly conformal distributions can be generated in a very effective way.
引用
收藏
页码:951 / 962
页数:12
相关论文
共 16 条
[1]   DOSE VOLUME HISTOGRAM ANALYSIS OF LIVER RADIATION TOLERANCE [J].
AUSTINSEYMOUR, MM ;
CHEN, GTY ;
CASTRO, JR ;
SAUNDERS, WM ;
PITLUCK, S ;
WOODRUFF, KH ;
KESSLER, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1986, 12 (01) :31-35
[2]  
BARTH NH, 1990, INT J RADIAT ONCOL, V18, P425, DOI 10.1016/0360-3016(90)90111-V
[3]   Treatment with gamma knife versus stereotactic linear accelerator. Clinical results and the cost-effectiveness [J].
Becker, G ;
Kortmann, R ;
Kaulich, TW ;
Duffner, F ;
Bamberg, M .
RADIOLOGE, 1996, 36 (04) :345-353
[4]   STEREOTACTIC RADIOSURGERY WITH THE LINEAR-ACCELERATOR - TREATMENT OF ARTERIOVENOUS-MALFORMATIONS [J].
BETTI, OO ;
MUNARI, C ;
ROSLER, R .
NEUROSURGERY, 1989, 24 (03) :311-321
[5]  
CAROL MP, 1992, INT J RAD ONCOL BIO, V24
[6]  
CRAIG JJ, 1982, ROBOTICS MECH CONTRO
[7]   A GENERALIZED PENCIL BEAM ALGORITHM FOR OPTIMIZATION OF RADIATION-THERAPY [J].
GUSTAFSSON, A ;
LIND, BK ;
BRAHME, A .
MEDICAL PHYSICS, 1994, 21 (03) :343-357
[8]  
KHAN FM, 1984, PHYSICS RAD THERAPY
[9]   A SYSTEM FOR STEREOTACTIC RADIOSURGERY WITH A LINEAR-ACCELERATOR [J].
LUTZ, W ;
WINSTON, KR ;
MALEKI, N .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (02) :373-381
[10]  
Menguy Y, 1997, LECT NOTES COMPUT SC, V1205, P675