Low order harmonic cancellation in a grid connected multiple inverter system via current control parameter randomization

被引:27
作者
Armstrong, M [1 ]
Atkinson, DJ
Johnson, CM
Abeyasekera, TD
机构
[1] Newcastle Univ, Sch Elect Elect & Comp Engn, Dept Elect & Elect Engn, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
[2] Univ Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
low order harmonics; multiple inverter systems; net harmonics;
D O I
10.1109/TPEL.2005.850949
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In grid connected multiple inverter systems, it is normal to synchronize the output current of each inverter to the common network voltage. Any current controller deficiencies, which result in low order harmonics, are also synchronized to the common network voltage. As a result the harmonics produced by individual converters show a high degree of correlation and tend to be additive. Each controller can be tuned to achieve a different harmonic profile so that harmonic cancellation can take place in the overall system, thus reducing the net current total harmonic distortion level. However, inter-inverter communication is required. This paper presents experimental results demonstrating an alternative approach, which is to arrange for the tuning within each inverter to be adjusted automatically with a random component. This results in a harmonic output spectrum that varies with time, but is uncorrelated with the harmonic spectrum of any other inverter in the system. The net harmonics from all the inverters undergo a degree of cancellation and the overall system yields a net improvement in power quality.
引用
收藏
页码:885 / 892
页数:8
相关论文
共 17 条
[1]  
[Anonymous], 1983, IEEE T POWER AP SYST, V102, P2455, DOI 10.1109/TPAS.1983.317745
[2]  
[Anonymous], 1985, IEEE T POWER AP SYST, V104, P2555, DOI 10.1109/TPAS.1985.319019
[3]   CURRENT AND VOLTAGE HARMONIC MEASUREMENTS AND MODELING AT THE GARDNER PHOTOVOLTAIC PROJECT [J].
CYGANSKI, D ;
ORR, JA ;
CHAKRAVORTI, AK ;
EMANUEL, AE ;
GULACHENSKI, EM ;
ROOT, CE ;
BELLEMARE, RC .
IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (01) :800-809
[4]  
*EL ASS UK, 2000, REC CONN SINGL PHAS
[5]  
ENDERS W, 2001, P 17 EUR SOL EN C EX
[6]  
Gallo D, 2000, 2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, P1581, DOI 10.1109/PESW.2000.847578
[7]  
Haeberlin H., 2001, P 17 EUR PHOT SOL EN, P426
[8]  
HOLMES DG, 1999, P IEEE 34 ANN IND AP, V2, P781
[9]   Combined switching harmonics from multiple grid-connected single-phase inverters [J].
Infield, DG .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2001, 148 (05) :427-430
[10]  
KEMPE A, 1996, P 25 IEEE PHOT SPEC, P1343