Capture window in human atrial fibrillation: Evidence of an excitable gap

被引:32
作者
Capucci, A [1 ]
Ravelli, F
Nollo, G
Montenero, AS
Biffi, M
Villani, GQ
机构
[1] Osped Civile, Div Cardiol, I-29100 Piacenza, Italy
[2] ITC Irst, Med Biophys Div, Trento, Italy
[3] Univ Bologna, Inst Cardiovasc Dis, Bologna, Italy
关键词
fibrillation; atrium; pacing; reentry;
D O I
10.1111/j.1540-8167.1999.tb00678.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Capture Window in Human AF. Introduction: Local capture of atrial fibrillation (AF) was shown in animal experiments for a wide range of pacing rates, thus demonstrating the existence of an excitable gap. The aim of this study was to assess the existence of an excitable gap in human AF by studying the mechanism bf local control and acceleration of AF over a wide range of pacing rates and by evaluating the time window of capture. Methods and Results: Recording and stimulation of electrical activity in the right atrium during AF was performed by a monophasic action potential (MAP) contact electrode catheter in 17 patients with lone AF during electrophysiologic study. Stimulation was started at pacing intervals close to the mean AF interval, and the time window of capture was estimated by lengthening or shortening the pacing interval until capture was lost. Pacing intervals shorter than the minimum cycle length for capture were also tested. Beat-to-beat measurements of AF intervals during pacing were performed. Atrial MAP signal showed rapid irregular activity with an average AF interval of 151.3 +/- 16.1 msec and SD of 21.3 +/- 5.2 msec, Rapid pacing with a cycle length slightly shorter or longer than the mean AF interval resulted in local capture of AF. The width of time window of capture ranged from 22 to 36 msec, with a mean value of 28.8 +/- 4.9 msec, The average minimum pacing interval of stable capture was 129.2 +/- 19.5 msec, while the maximum was 158.1 +/- 18.7 msec, corresponding to 85% and 104% of mean AF cycle length, respectively. Pacing too rapidly resulted in a transient acceleration of AF, with an average shortening of fibrillation interval from 149.8 +/- 16.6 to 123.2 +/- 15.1 msec (P < 0.01). Conclusion: Local capture is feasible during AF in humans over a wide range of pacing rates, indicating the possibility of regional control of the fibrillatory process. This result demonstrates the presence of an excitable gap during AF in human atria.
引用
收藏
页码:319 / 327
页数:9
相关论文
共 26 条
[1]   REGIONAL CONTROL OF ATRIAL-FIBRILLATION BY RAPID PACING IN CONSCIOUS DOGS [J].
ALLESSIE, M ;
KIRCHHOF, C ;
SCHEFFER, GJ ;
CHORRO, F ;
BRUGADA, J .
CIRCULATION, 1991, 84 (04) :1689-1697
[2]  
[Anonymous], 1985, Cardiac arrhythmias
[3]   DYNAMIC ELECTROPHYSIOLOGICAL BEHAVIOR OF HUMAN ATRIA DURING PAROXYSMAL ATRIAL-FIBRILLATION [J].
CAPUCCI, A ;
BIFFI, M ;
BORIANI, G ;
RAVELLI, F ;
NOLLO, G ;
SABBATANI, P ;
ORSI, C ;
MAGNANI, B .
CIRCULATION, 1995, 92 (05) :1193-1202
[4]   DIRECTIONAL DIFFERENCES OF IMPULSE SPREAD IN TRABECULAR MUSCLE FROM MAMMALIAN HEART [J].
CLERC, L .
JOURNAL OF PHYSIOLOGY-LONDON, 1976, 255 (02) :335-346
[5]   Response of type I atrial fibrillation to atrial pacing in humans [J].
Daoud, EG ;
Pariseau, B ;
Niebauer, M ;
Bogun, F ;
Goyal, R ;
Harvey, M ;
Man, KC ;
Strickberger, SA ;
Morady, F .
CIRCULATION, 1996, 94 (05) :1036-1040
[6]   A NEW SINGLE CATHETER TECHNIQUE FOR SIMULTANEOUS MEASUREMENT OF ACTION-POTENTIAL DURATION AND REFRACTORY PERIOD INVIVO [J].
FRANZ, MR ;
CHIN, MC ;
SHARKEY, HR ;
GRIFFIN, JC ;
SCHEINMAN, MM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (04) :878-886
[7]   INVITRO VALIDATION OF A NEW CARDIAC CATHETER TECHNIQUE FOR RECORDING MONOPHASIC ACTION-POTENTIALS [J].
FRANZ, MR ;
BURKHOFF, D ;
SPURGEON, H ;
WEISFELDT, ML ;
LAKATTA, EG .
EUROPEAN HEART JOURNAL, 1986, 7 (01) :34-41
[8]   EFFICACY OF AMIODARONE FOR REFRACTORY SUPRA-VENTRICULAR TACHYARRHYTHMIAS [J].
GRABOYS, TB ;
PODRID, PJ ;
LOWN, B .
AMERICAN HEART JOURNAL, 1983, 106 (04) :870-876
[9]   Regional entrainment of atrial fibrillation in man [J].
Kalman, JM ;
Olgin, JE ;
Karch, MR ;
Lesh, MD .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (09) :867-876
[10]   REGIONAL CAPTURE OF FIBRILLATING VENTRICULAR MYOCARDIUM - EVIDENCE OF AN EXCITABLE GAP [J].
KENKNIGHT, BH ;
BAYLY, PV ;
GERSTLE, RJ ;
ROLLINS, DL ;
WOLF, PD ;
SMITH, WM ;
IDEKER, RE .
CIRCULATION RESEARCH, 1995, 77 (04) :849-855