Thermal performance analysis of the glass evacuated tube solar collector with U-tube

被引:194
作者
Ma, Liangdong [1 ]
Lu, Zhen [1 ]
Zhang, Jili [1 ]
Liang, Ruobing [1 ]
机构
[1] Dalian Univ Technol, Sch Civil & Hydraul Engn, Dalian, Peoples R China
关键词
Thermal performance analysis; Glass evacuated tube; Solar collector; U-tube; VACUUM TUBES;
D O I
10.1016/j.buildenv.2010.01.015
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, based on the energy balance for the glass evacuated tube solar collector with U-tube, the thermal performance of the individual glass evacuated tube solar collector is investigated by analytical method. The solar collector considered in this study is a two-layered glass evacuated tube, and the absorber film is deposited in the outer surface of the absorber tube. The heat loss coefficient and heat efficiency factor are analyzed using one-dimensional analytical solution. And the influence of air layer between the absorber tube and the copper fin on the heat efficiency is also studied. The results show that the function relation of the heat loss coefficient of the glass evacuated tube solar collector with temperature difference between the absorbing coating surface and the ambient air is nonlinear. In the different ambient temperatures, the heat loss coefficient of the solar collector should be calculated by different expressions. The heat efficiency factor will be subject to influence of air layer between absorber tube and the copper fin. Specially, the influence is remarkable when the heat loss coefficient of the collector is large. When the synthetical conductance amounts to 5 W/m K, the solar collector efficiency decreases 10%, and the outlet fluid temperature decreases 16% compared with the case which the air thermal resistance is neglected. And the surface temperature of the absorbing coating increases 30 C due to the effect of air thermal resistance. So the surface temperature of the absorbing coating is an important parameter to evaluate the thermal performance of the glass evacuated tube solar collector. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1959 / 1967
页数:9
相关论文
共 13 条
[1]  
[Anonymous], 1980, SOLAR ENG THERMAL PR
[2]   On the measurement of bond conductance in solar collector absorber plate [J].
Badran, Ali A. ;
Mustafa, Mohammed F. ;
Dawood, Walid K. ;
Ghazzawi, Zaid K. .
ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (11) :3305-3310
[3]   Performance study of a bi-directional thermodiode designed for energy-efficient buildings [J].
Chun, W ;
Chen, K ;
Kim, HT .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (03) :291-299
[4]  
DIAZ G, 2008, P ASME IMECE 2008 OC
[5]   A three-dimensional performance analysis of all-glass vacuum tubes with coaxial fluid conduit [J].
Han, Hyunjoo ;
Kim, Jeong Tai ;
Ahn, Hyun Tae ;
Lee, Sang Jin .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2008, 35 (05) :589-596
[6]  
He ZN, 1997, SOL ENERGY, V60, P109, DOI 10.1016/S0038-092X(96)00160-0
[7]   The performance simulation of all-glass vacuum tubes with coaxial fluid conduit [J].
Kim, Jeong Tai ;
Ahn, Hyun Tae ;
Han, Hyunjoo ;
Kim, Hyung Taek ;
Chun, Wongee .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2007, 34 (05) :587-597
[8]   Thermal performances comparisons of the glass evacuated tube solar collectors with shapes of absorber tube [J].
Kim, Yong ;
Seo, Taebeom .
RENEWABLE ENERGY, 2007, 32 (05) :772-795
[9]   Vertical evacuated tubular-collectors utilizing solar radiation from all directions [J].
Shah, LJ ;
Furbo, S .
APPLIED ENERGY, 2004, 78 (04) :371-395
[10]   Theoretical flow investigations of an all glass evacuated tubular collector [J].
Shah, Louise Jivan ;
Furbo, Simon .
SOLAR ENERGY, 2007, 81 (06) :822-828