Vitek 2 ANC card versus BBL Crystal Anaerobe and RapID ANA II for identification of clinical anaerobic bacteria

被引:16
作者
Blairon, Laurent [1 ,2 ]
Maza, Mengi L. [1 ,2 ]
Wybo, Ingrid [3 ]
Pierard, Denis [3 ]
Dediste, Anne [1 ,2 ]
Vandenberg, Olivier [1 ,2 ]
机构
[1] St Pierre Univ Hosp, Dept Microbiol, B-1000 Brussels, Belgium
[2] Inst Jules Bordet, B-1000 Brussels, Belgium
[3] UZ Brussel Univ Hosp, Dept Microbiol, Brussels, Belgium
关键词
Anaerobes; Panels; Identification automate; Identification; Confidence factor;
D O I
10.1016/j.anaerobe.2010.05.001
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The Vitek 2 Anaerobe and Corynebacterium Identification Card (ANC) was recently evaluated in a multicentre study. In the present work, this system was compared with the BBL Crystal Anaerobe and RapID ANA II panels. These kits were tested using 196 strains of anaerobes that had been previously identified by gas liquid chromatography. Identification to the species or to the genus level was 75.0%, 81.1% and 70.9% for Crystal, RapID and Vitek, respectively. Vitek ANC failed to provide any identification in 20.4% of the strains, but it had fewer misidentifications than RapID. The confidence factors provided on the results report of each kit were not always correlated with a lower risk of major errors, with the exception of Vitek 2 in which a confidence factor higher than 0.86 excluded the risk of misidentification in more than 87% of isolates. The lower rate of identification by the Vitek and Crystal panels is mostly due the lower ability of these system to identify the Clostridia. Overall, the three panels are comparable but need improvement to a better accuracy. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:355 / 361
页数:7
相关论文
共 12 条
  • [1] A 62-month retrospective epidemiological survey of anaerobic bacteraemia in a university hospital
    Blairon, L.
    De Gheldre, Y.
    Delaere, B.
    Sonet, A.
    Bosly, A.
    Glupczynski, Y.
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2006, 12 (06) : 527 - 532
  • [2] Evaluation of the BBL crystal anaerobe identification system
    Cavallaro, JJ
    Wiggs, LS
    Miller, JM
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (12) : 3186 - 3191
  • [3] CLINICAL-EVALUATION OF THE RAPID-ANA-II PANEL FOR IDENTIFICATION OF ANAEROBIC-BACTERIA
    CELIG, DM
    SCHRECKENBERGER, PC
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (03) : 457 - 462
  • [4] Lorber B., 2000, PRINCIPLES PRACTICE, P2561
  • [5] Evaluation of the New Vitek 2 ANC Card for Identification of Medically Relevant Anaerobic Bacteria
    Mory, Francine
    Alauzet, Corentine
    Matuszeswski, Celine
    Riegel, Philippe
    Lozniewski, Alain
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (06) : 1923 - 1926
  • [6] Antimicrobial resistance and clinical outcome of bacteroides bacteremia: Findings of a multicenter prospective observational trial
    Nguyen, MH
    Yu, VL
    Morris, AJ
    McDermott, L
    Wagener, MW
    Harrell, L
    Snydman, DR
    [J]. CLINICAL INFECTIOUS DISEASES, 2000, 30 (06) : 870 - 876
  • [7] O'Hara C.M., 2003, Manual of Clinical Microbiology, V8th, P185
  • [8] Multicenter evaluation of the Vitek 2 anaerobe and Corynebacterium identification card
    Rennie, Robert P.
    Brosnikoff, Cheryl
    Turnbull, LeeAnn
    Reller, L. Barth
    Mirrett, Stanley
    Janda, William
    Ristow, Kathy
    Krilcich, Ann
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (08) : 2646 - 2651
  • [9] Clinical significance and outcome of anaerobic bacteremia
    Salonen, JH
    Eerola, E
    Meurman, O
    [J]. CLINICAL INFECTIOUS DISEASES, 1998, 26 (06) : 1413 - 1417
  • [10] CLINICAL-EVALUATION OF THE VITEK ANI CARD FOR IDENTIFICATION OF ANAEROBIC-BACTERIA
    SCHRECKENBERGER, PC
    CELIG, DM
    JANDA, WM
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1988, 26 (02) : 225 - 230