Microwave assisted extraction of drugs of abuse from human urine

被引:28
作者
Fernandez, Purificacion
Lago, Marta
Lorenzo, Rosa Antonia
Carro, Antonia Maria
Bermejo, Ana Maria
Tabernero, Maria Jesus
机构
[1] Fac Med, Forens Toxicol Serv, Inst Legal Med, Santiago De Compostela 15782, Spain
[2] Fac Chem, Dept Analyt Chem, Santiago De Compostela 15782, Spain
关键词
MAE; HPLC-DAD; gradient; urine; drugs of abuse; CHROMATOGRAPHY-MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; DIODE-ARRAY-DETECTION; SOLID-PHASE EXTRACTION; COCAINE; BENZOYLECGONINE; METABOLITES; COCAETHYLENE; PLASMA; SYSTEM;
D O I
10.1002/jat.1216
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Microwave assisted extraction (MAE) was used to extract drugs of abuse from urine samples for the simultaneous determination of morphine, codeine, 6-acetylmorphine (6AM), cocaine, cocaethylene, benzoylecgonine (BEG), methadone and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) by high performance liquid chromatography with diode array detector (HPLC-DAD). The working wavelengths use were 285 nm for morphine, codeine and 6AM; 233 nm for cocaine, cocaethylene and BEG; and 292 nm for methadone and EDDP. The mobile phase was a gradient of acetonitrile and phosphate buffer at pH 6.5. A full factorial design was used to identify the most suitable extraction conditions as regards pH, solvent and time of extraction. The optimum conditions thus established provided analyte recoveries from 61% to 109%. The detector response was linear over the drug concentration range 0.1-4.0 mu g ml(-1) in urine. The within- and between-day precision and accuracy were less than 8% and 6.5%, respectively. The method was applied successfully to samples obtained from Galician hospitals and courts. Copyright (C) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:373 / 379
页数:7
相关论文
共 26 条
[1]   Analysis of cocaethylene, benzoylecgonine and cocaine in human urine by high-performance thin-layer chromatography with ultraviolet detection: a comparison with high-performance liquid chromatography [J].
Antonilli, L ;
Suriano, C ;
Grassi, MC ;
Nencini, P .
JOURNAL OF CHROMATOGRAPHY B, 2001, 751 (01) :19-27
[2]   Focused microwave-assisted extraction of cocaine and benzoylecgonine from coca leaves [J].
Brachet, A ;
Christen, P ;
Veuthey, JL .
PHYTOCHEMICAL ANALYSIS, 2002, 13 (03) :162-169
[3]   Validation of liquid chromatographic and gas chromatographic methods - Applications to pharmacokinetics [J].
Bressolle, F ;
BrometPetit, M ;
Audran, M .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (01) :3-10
[4]   Determination of cocaine and benzoylecgonine by direct injection of human urine into a column-switching liquid chromatography system with diode-array detection [J].
Brunetto, MR ;
Cayama, YD ;
García, LG ;
Gallignani, M ;
Obando, MA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (01) :115-120
[5]  
Cardenas S, 1996, RAPID COMMUN MASS SP, V10, P631, DOI 10.1002/(SICI)1097-0231(199604)10:6<631::AID-RCM524>3.3.CO
[6]  
2-K
[7]   Determination of drugs of abuse and their metabolites in human plasma by liquid chromatography-mass spectrometry -: An application to 156 road fatalities [J].
Concheiro, M ;
de Castro, A ;
Quintela, O ;
López-Rivadulla, M ;
Cruz, A .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 832 (01) :81-89
[8]   In vivo adulteration: Excess fluid ingestion causes false-negative marijuana and cocaine urine test results [J].
Cone, EJ ;
Lange, R ;
Darwin, WD .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1998, 22 (06) :460-473
[9]  
CONE EJ, 1994, CLIN CHEM, V40, P1299
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY DETERMINATION FOLLOWING MICROWAVE-ASSISTED EXTRACTION OF 3-NITRO-4-HYDROXYPHENYLARSONIC ACID FROM SWINE LIVER, KIDNEY, AND MUSCLE [J].
CROTEAU, LG ;
AKHTAR, MH ;
BELANGER, JMR ;
PARE, JRJ .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (13) :2971-2981