Electrocoagulation for removal of silica nano-particles from chemical-mechanical-planarization wastewater

被引:65
作者
Den, W
Huang, CP
机构
[1] Tunghai Univ, Dept Environm Sci, Taichung 407, Taiwan
[2] Natl Chiao Tung Univ, Inst Environm Engn, Hsinchu, Taiwan
关键词
electrocoagulation; electrochemical; parallel plate; monopolar; silica colloids; chemical-mechanical-planarization; CMP wastewater treatment;
D O I
10.1016/j.colsurfa.2004.11.026
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Continuous-flow electrocoagulation process with vertical flow-channels was investigated as a method to treat synthetic chemical-mechanical-planarization (CMP) wastewater containing highly charged ultrafine silica particles (zeta = -55 mV, mean R-p = 45 nm at pH 9.5). The parallel-plate, monopolar electrochemical cells resembled a series of closed electrical circuits such that the electrical field strength was highly dependent of the current density and aqueous conductivity, but independent of the inter-electrode gap. The residual turbidity of the CMP wastewater decreased with the increases in either hydraulic retention time or applied current density, and removal efficiency as high as 95% was achieved for wastewater with both low (70NTU) and high (400 NTU) initial turbidities. The charge loading linearly correlated with turbidity removal efficiency up to a level of 8 F m(-3), presenting an appropriate design parameter. Further analysis indicated that turbidity removal was limited by the quantity of liberated ferrous ions at lower range of current density, but seemingly reached a critical level of current density beyond which the process performance gradually deteriorated. Comparisons between the effective particle retention time and the estimated electrophoretic migration time revealed that the electrocoagulation process was predominantly controlled by the rate of particle aggregation occurring near the anodic surfaces. Furthermore, this process generates lesser amount of dry sludge as compared to chemical coagulation with polyaluminum chloride, and does not require pH adjustment prior to treatment. (C) 2004 Elsevier B.V.. All rights reserved.
引用
收藏
页码:81 / 89
页数:9
相关论文
共 19 条
[1]   Treatment of alumina and silica chemical mechanical polishing waste by electrodecantation and electrocoagulation [J].
Belongia, BM ;
Haworth, PD ;
Baygents, JC ;
Raghavan, S .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1999, 146 (11) :4124-4130
[2]  
Browne S, 1999, MICRO, V17, P77
[3]   Investigation on the electrolysis voltage of electrocoagulation [J].
Chen, XM ;
Chen, GH ;
Yue, PL .
CHEMICAL ENGINEERING SCIENCE, 2002, 57 (13) :2449-2455
[4]  
DEN W, 2002, P 9 INT SEM ENV HLTH
[5]   Developing and testing electrochemical methods for treating metal salts, cyanides and organic compounds in waste streams [J].
Dziewinski, J ;
Marczak, S ;
Nuttall, E ;
Purdy, G ;
Smith, W ;
Taylor, J ;
Zhou, C .
WASTE MANAGEMENT, 1998, 18 (04) :257-263
[6]  
Golden J. H., 2000, Semiconductor International, V23, P85
[7]  
GOLDEN JH, 2001, SEMICOND FABTECH, V13, P123
[8]  
Hiemenz P.C., 2016, PRINCIPLES COLLOID S, DOI 10.1201/9781315274287
[9]  
JIANG W, 2001, P INT WAT ASS AS ENV
[10]   Time requirement for rapid-mixing in coagulation [J].
Kan, CC ;
Huang, CP ;
Pan, JRS .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2002, 203 (1-3) :1-9