Internal calibration on adjacent samples (InCAS) with Fourier transform mass spectrometry

被引:70
作者
O'Connor, PB [1 ]
Costello, CE [1 ]
机构
[1] Boston Univ, Sch Med, Dept Biochem, Mass Spectrometry Resource, Boston, MA 02118 USA
关键词
D O I
10.1021/ac000770t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Using matrix-assisted laser desorption/ionization (MAG DI) on a trapped ion mass spectrometer such as a Fourier transform mass spectrometer (FTMS) allows accumulation of ions in the cell from multiple laser shots prior to detection. If ions from separate MALDI samples are accumulated simultaneously in the cell, ions from one sample can be used to calibrate ions from the other sample. Since the ions are detected simultaneously in the cell, this is, in effect, internal calibration, but there are no selective desorption effects in the MALDI source. This method of internal calibration with adjacent samples is demonstrated here on cesium iodide clusters, peptides, oligosaccharides,poly(propylene glycol), and fullerenes and provides typical FTMS internal calibration mass accuracy of < 1 ppm.
引用
收藏
页码:5881 / 5885
页数:5
相关论文
共 19 条
  • [1] Infrared MALDI mass spectrometry of large nucleic acids
    Berkenkamp, S
    Kirpekar, F
    Hillenkamp, F
    [J]. SCIENCE, 1998, 281 (5374) : 260 - 262
  • [2] OPEN TRAPPED ION CELL GEOMETRIES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY
    BEU, SC
    LAUDE, DA
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 112 (2-3): : 215 - 230
  • [3] Obtaining more accurate Fourier transform ion cyclotron resonance mass measurements without internal standards using multiply charged ions
    Bruce, JE
    Anderson, GA
    Brands, MD
    Pasa-Tolic, L
    Smith, RD
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (05) : 416 - 421
  • [4] ULTRAHIGH-RESOLUTION MATRIX-ASSISTED LASER-DESORPTION IONIZATION OF SMALL PROTEINS BY FOURIER-TRANSFORM MASS-SPECTROMETRY
    CASTORO, JA
    WILKINS, CL
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (19) : 2621 - 2627
  • [5] Routine part-per-million mass accuracy for high-mass ions: Space-charge effects in MALDI FT-ICR
    Easterling, ML
    Mize, TH
    Amster, IJ
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (03) : 624 - 632
  • [6] MALDI MS and strategies for protein analysis
    Fenselau, C
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (21) : A661 - A665
  • [7] Harvey DJ, 1999, MASS SPECTROM REV, V18, P349, DOI 10.1002/(SICI)1098-2787(1999)18:6<349::AID-MAS1>3.3.CO
  • [8] 2-8
  • [9] HILLENKAMP F, 1991, ANAL CHEM, V63, pA1193
  • [10] Ion transport through a strong magnetic field gradient by rf-only octupole ion guides
    Huang, YL
    Guan, SH
    Kim, HS
    Marshall, AG
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1996, 152 (2-3) : 121 - 133