Relationship between energy cost, gait speed, vertical displacement of centre of body mass and efficiency of pendulum-like mechanism in unilateral amputee gait

被引:63
作者
Detrembleur, C
Vanmarsenille, JM
De Cuyper, F
Dierick, F
机构
[1] Catholic Univ Louvain, Rehabil & Phys Med Unit, B-1200 Brussels, Belgium
[2] SA Orthoped Van Haesendonck, Louvain, Belgium
[3] Clin Univ St Luc, Dept Phys Med & Rehabil, Brussels, Belgium
关键词
energy cost; pendulum mechanism; amputee; gait;
D O I
10.1016/j.gaitpost.2004.04.005
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The energy cost of gait (C) is greater in amputee than in normal subjects. Our objective was to assess the influence of lower speed, inefficient pendulum mechanism and disturbed smoothness of centre of body mass (M) displacement on C in unilateral amputees and to have a better understanding the relationship between these variables. Twelve adult patients (six traumatic transfemoral and six vascular transtibial amputees) participated in the study. Lower limb kinematics, displacement Of CMb, mechanical work done by the muscles to move the CMb and the segments due to their movements relative to the CMb, efficiency of the pendulum mechanism, and C were assessed simultaneously in the 12 amputees walking at their self-selected speed. Our results show that C depended on gait speed, and efficiency of pendulum-like mechanism of walking but did not depend on the smoothness of CMb. The use of only a single variable to explain the extra cost in amputee gait could sometimes be misleading. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:333 / 340
页数:8
相关论文
共 32 条
[1]   Data management in gait analysis for clinical applications [J].
Benedetti, MG ;
Catani, F ;
Leardini, A ;
Pignotti, E ;
Giannini, S .
CLINICAL BIOMECHANICS, 1998, 13 (03) :204-215
[2]   Oxygen consumption during ambulation: Comparison of using a prosthesis fitted with and without a tele-torsion device [J].
Buckley, JG ;
Jones, SF ;
Birch, KM .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (04) :576-581
[3]   FORCE PLATFORMS AS ERGOMETERS [J].
CAVAGNA, GA .
JOURNAL OF APPLIED PHYSIOLOGY, 1975, 39 (01) :174-179
[4]   SOURCES OF EXTERNAL WORK IN LEVEL WALKING AND RUNNING [J].
CAVAGNA, GA ;
THYS, H ;
ZAMBONI, A .
JOURNAL OF PHYSIOLOGY-LONDON, 1976, 262 (03) :639-657
[5]   ANALYSIS OF MECHANICAL AND METABOLIC FACTORS IN THE GAIT OF CONGENITAL BELOW KNEE AMPUTEES - A COMPARISON OF THE SACH AND SEATTLE FEET [J].
COLBORNE, GR ;
NAUMANN, S ;
LONGMUIR, PE ;
BERBRAYER, D .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1992, 71 (05) :272-278
[6]   TECHNIQUE FOR THE EVALUATION OF DERIVATIVES FROM NOISY BIOMECHANICAL DISPLACEMENT DATA USING A MODEL-BASED BANDWIDTH-SELECTION PROCEDURE [J].
DAMICO, M ;
FERRIGNO, G .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (05) :407-415
[7]   A GAIT ANALYSIS DATA-COLLECTION AND REDUCTION TECHNIQUE [J].
DAVIS, RB ;
OUNPUU, S ;
TYBURSKI, D ;
GAGE, JR .
HUMAN MOVEMENT SCIENCE, 1991, 10 (05) :575-587
[8]   The energy cost of walking in children [J].
DeJaeger, D ;
Willems, PA ;
Heglund, NC .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2001, 441 (04) :538-543
[9]  
Della Croce U, 2001, GAIT POSTURE, V14, P79
[10]   KINETIC-ANALYSIS OF THE LOWER-LIMBS DURING WALKING - WHAT INFORMATION CAN BE GAINED FROM A 3-DIMENSIONAL MODEL [J].
ENG, JJ ;
WINTER, DA .
JOURNAL OF BIOMECHANICS, 1995, 28 (06) :753-758