Performance of a full-scale biotrickling filter treating H2S at a gas contact time of 1.6 to 2.2 seconds

被引:86
作者
Gabriel, D [1 ]
Deshusses, MA [1 ]
机构
[1] Univ Calif Riverside, Dept Chem & Environm Engn, Riverside, CA 92521 USA
来源
ENVIRONMENTAL PROGRESS | 2003年 / 22卷 / 02期
关键词
D O I
10.1002/ep.670220213
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Emission of objectionable odors is a major problem for wastewater treatment and other processing facilities. Biological treatment is a promising alternative to conventional control methods, such as chemical scrubbing, but historically, biotreatment has always required significantly larger reactor volumes than chemical scrubbers. In this paper we present several aspects of the operation and performance of a chemical scrubber, retrofitted to operate as a biotrickling filter treating 161, 000 m(3) h(-1) of foul air with the original gas contact time of 1.6 to 2.2 seconds, In continuous operation for more than a year, the biotrickling filter has shown stable performance and robust behavior for H2S treatment, with pollutant removal performance comparable to using a chemical scrubber, performance comparable to using chemical scrubber. Reclaimed water was used as a nutrient source for the process. and to maintain the pH in the biotrickling,filter between 1.5 and 2.2, At a gas contact Nine of 1.6 seconds, H2S removal was in excess of 95% for sustained inlet H2S concentrations as high as 30 ppm(nu). This corresponds to volumetric elimination rates of 95 to 105 g H2S m(-3) h(-1). Ffficiencies of about 90% were observed under transient conditions at 2.2 seconds gas contact time for inlet concentration peaks lip to 60 ppm(nu) The biotrickling filter also removed significant amounts of reduced sulfur compounds, ammonia, and volatile organic compounds present in traces in the air, which is important in practical applications, Selected experiments, such as intermittent trickling operation and a one-month, operation period at neutral pH, are also presented. Results indicate that the intermittent trickling operation does not have a significant effect on H2S removal. operation does not have a significant However, when operated at neutral pH, biotrickling filter performance clearly decreased, probably due to an excessive chlorine supply to The reactor through the make-up water. The study, demonstrates That biotrickling filters can replace chemical scrubbers as a safer more economical technique for odor control.
引用
收藏
页码:111 / 118
页数:8
相关论文
共 16 条
[1]   THIOSULFATE UTILIZATION BY THIOBACILLUS THIOOXIDANS ATCC 8085 [J].
BARTON, LL ;
SHIVELY, JM .
JOURNAL OF BACTERIOLOGY, 1968, 95 (02) :720-&
[2]  
Card T., 2001, ODOURS WASTEWATER TR, P309
[3]   Co-treatment of H2S and toluene in a biotrickling filter [J].
Cox, HHJ ;
Deshusses, MA .
CHEMICAL ENGINEERING JOURNAL, 2002, 87 (01) :101-110
[4]  
Devinny JS., 1999, BIOFILTRATION AIR PO
[5]   Treatment of methyl tert-butyl ether vapors in biotrickling filters.: 1.: Reactor startup, steady state performance, and culture characteristics [J].
Fortin, NY ;
Deshusses, MA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (17) :2980-2986
[6]  
GABRIEL D, IN PRESS J ENV ENG
[7]  
GABRIEL D, 2002, P OD TOX AIR EM 2002
[8]   MICROBIAL ECOLOGY OF CROWN CORROSION IN SEWERS [J].
ISLANDER, RL ;
DEVINNY, JS ;
MANSFELD, F ;
POSTYN, A ;
HONG, S .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1991, 117 (06) :751-770
[9]   A bioscrubber for hydrogen sulphide removal [J].
Koe, LCC ;
Yang, F .
WATER SCIENCE AND TECHNOLOGY, 2000, 41 (06) :141-145
[10]  
Lobo R, 1999, BIOTECHNOL BIOENG, V63, P98, DOI 10.1002/(SICI)1097-0290(19990405)63:1<98::AID-BIT10>3.3.CO