A submillimeter polychromator for plasma spectroscopy

被引:14
作者
Tudisco, O
Berton, F
Buratti, P
Grilli, E
Mantovani, S
机构
[1] Assoc. EURATOM-ENEA sulla Fusione C., 00044-Frascati (Rome)
关键词
D O I
10.1063/1.1147436
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A 12-channel grating polychromator for the measurement of electron cyclotron emission on the Frascati tokamak upgrade (FTU) has been built. Three gratings can be exchanged remotely, to allow the instrument to cover three different spectral ranges (between 200 and 600 GHz) which correspond to the second harmonic of electron cyclotron emission for tokamak magnetic fields of 4, 6, and 8 T. Three sets of low-pass filters, whose cut-off frequencies are optimized for each grating, are used to cut the high diffraction orders. In order to exchange the filters together with the grating it was necessary to integrate the groups of filters with the polychromator itself. This has been done reducing the grating sizes and assembling them all closely on a moveable structure. The exchange of gratings and filters can be performed remotely via computer in few seconds without any lost of the alignment. InSb cryogenic hot-electron bolometers are used as detectors. The cryostat hold-time is more than 30 days. Spectral resolution lambda/delta lambda is about 40 corresponding to a spatial resolution of delta R approximate to 2.3 cm. The minimum detectable temperature is about 10 eV at 20 kHz bandwidth. The spatial structure and temporal evolution of several kinds of fast temperature perturbations (as the ones due to magnetohydrodynamic activity, temperature fall during pellet injection and plasma disruption) have been measured on FTU by means of this diagnostic system. (C) 1996 American Institute of Physics.
引用
收藏
页码:3108 / 3116
页数:9
相关论文
共 17 条
[1]  
ANDREANI R, 1991, FUSION TECHNOLOGY 19, V1, P218
[2]  
[Anonymous], COMMUNICATION
[3]   ELECTRON-CYCLOTRON EMISSION AND ABSORPTION IN FUSION PLASMAS [J].
BORNATICI, M ;
CANO, R ;
DEBARBIERI, O ;
ENGELMANN, F .
NUCLEAR FUSION, 1983, 23 (09) :1153-1257
[4]   A FOURIER-TRANSFORM SPECTROMETER WITH FAST SCANNING CAPABILITY FOR TOKAMAK PLASMA DIAGNOSTIC [J].
BURATTI, P ;
ZERBINI, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (08) :4208-4217
[5]   A BROAD-BAND LIGHT COLLECTION SYSTEM FOR ECE DIAGNOSTICS ON THE FTU TOKAMAK [J].
BURATTI, P ;
TUDISCO, O ;
ZERBINI, M .
INFRARED PHYSICS, 1993, 34 (05) :533-541
[6]   20-CHANNEL GRATING POLYCHROMATOR FOR MILLIMETER WAVE PLASMA EMISSION MEASUREMENTS [J].
CAVALLO, A ;
CUTLER, RC ;
MCCARTHY, MP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (06) :889-894
[7]   A stigmatism in the mirror spectrometers. [J].
Czerny, M. ;
Turner, A. F. .
ZEITSCHRIFT FUR PHYSIK, 1930, 61 (11-12) :792-797
[8]   CYCLOTRON RADIATION FROM A RAREFIED INHOMOGENEOUS MAGNETOPLASMA [J].
ENGELMANN, F ;
CURATOLO, M .
NUCLEAR FUSION, 1973, 13 (04) :497-507
[9]   10-CHANNEL GRATING POLYCHROMATOR FOR ELECTRON-CYCLOTRON EMISSION PLASMA DIAGNOSTICS [J].
FISCHER, J ;
BOYD, DA ;
CAVALLO, A ;
BENSON, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1983, 54 (09) :1085-1090
[10]  
HELSTRON CW, 1968, STATISTICAL THEORY S, P102