Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography

被引:102
作者
Li, Haitao
Leung, Christopher Kai Shun
Cheung, Carol Yim Lui
Wong, Lee
Pang, Chi Pui
Weinreb, Robert Neal
Lam, Dennis Shun Chiu
机构
[1] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
[2] Univ Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, San Diego, CA 92103 USA
关键词
D O I
10.1136/bjo.2007.118901
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Aim: To evaluate the repeatability and reproducibility of anterior chamber angle measurement obtained by anterior segment optical coherence tomography. Methods: Twenty-five normal subjects were invited for anterior chamber angle imaging with an anterior segment optical coherence tomography (OCT) on one randomly selected eye in three separate visits within a week. Each eye was imaged three times under room light ( light intensity = 368 lux) and three times in the dark during the first visit. In the subsequent visits, each eye was imaged once in the light and once in the dark. The angle opening distance (AOD 500) and the trabecular-iris angle (TIA 500) were measured by a single observer. Only the nasal angle was analysed. Intrasession and intersession within-subject standard deviation (Sw), precision (1.96xSw), coefficient of variation (CVw) (1006Sw/overall mean), and intraclass correlation coefficient (ICC) were calculated to evaluate repeatability and reproducibility. Results: For intrasession repeatability, the Sw, precision, CVw and ICC of AOD/TIA were 45 mu m/2.4 degrees, 88 mu m/4.7 degrees, 5.8%/4.8% and 0.97/0.95 in the light; and 45 mu m/2.1 degrees, 88 mu m/4.2 degrees, 7.0%/5.0% and 0.98/0.97 in the dark. For intersession reproducibility, the Sw, precision, CVw and ICC of AOD/TIA were 79 mu m/3.5 degrees, 155 mu m/6.8 degrees, 10.0%/7.0%, 0.91/0.89 in the light; and 64 mu m/3.4 degrees, 124 mu m/6.6 degrees, 9.9%/7.8% and 0.95/0.92 in the dark. Conclusions: The anterior segment OCT demonstrated reliable anterior chamber angle measurement in different lighting conditions with good repeatability and reproducibility.
引用
收藏
页码:1490 / 1492
页数:3
相关论文
共 10 条
[1]
Angle recess area decreases with age in normal Japanese [J].
Esaki, K ;
Ishikawa, H ;
Liebmann, JM ;
Greenfield, DS ;
Uji, Y ;
Ritch, R .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2000, 44 (01) :46-51
[2]
Ishikawa H, 2000, OPHTHALMIC SURG LAS, V31, P342
[3]
Ultrasound biomicroscopy dark room provocative testing: A quantitative method for estimating anterior chamber angle width [J].
Ishikawa, H ;
Esaki, K ;
Liebmann, JM ;
Uji, Y ;
Ritch, R .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 1999, 43 (06) :526-534
[4]
Anterior chamber angle measurement with optical coherence tomography:: Intraobserver and interobserver variability [J].
Mueller, Maya ;
Dahmen, Gerlinde ;
Poerksen, Erk ;
Geerling, Gerd ;
Laqua, Horst ;
Ziegler, Andreas ;
Hoerauf, Hans .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) :1803-1808
[5]
ULTRASOUND BIOMICROSCOPY OF ANTERIOR SEGMENT STRUCTURES IN NORMAL AND GLAUCOMATOUS EYES [J].
PAVLIN, CJ ;
HARASIEWICZ, K ;
FOSTER, FS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 113 (04) :381-389
[6]
PAVLIN CJ, 1991, OPHTHALMOLOGY, V98, P287
[7]
PHILLIPS C I, 1956, Br J Ophthalmol, V40, P136, DOI 10.1136/bjo.40.3.136
[8]
TELLO C, 1994, INVEST OPHTH VIS SCI, V35, P3549
[9]
Ultrasound biomicroscopy. II. Intraobserver and interobserver reproducibility of measurements [J].
Urbak, SE ;
Pedersen, JK ;
Thorsen, TT .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 (05) :546-549
[10]
Ultrasound biomicroscopic quantitative analysis of light-dark changes associated with pupillary block [J].
Woo, EK ;
Pavlin, CJ ;
Slomovic, A ;
Taback, N ;
Buys, YM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 127 (01) :43-47