Assessment of objective and subjective eccentric refraction

被引:31
作者
Lundström, L
Gustafsson, J
Svensson, I
Unsbo, P
机构
[1] Royal Inst Technol, BIOX Biomed & Xray Phys, Dept Phys, S-10691 Stockholm, Sweden
[2] Lund Univ, Dept Design Sci, Certec Rehabil Engn Res, Lund, Sweden
关键词
peripheral vision; refractive errors; eccentric refraction; detection; contrast sensitivity; photorefraction; wavefront aberrations; retinoscopy;
D O I
10.1097/01.OPX.0000159366.61943.62
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. When performing perimetry, refracting subjects with central visual field loss, and in emmetropization studies, it is important to accurately measure peripheral refractive errors. Traditional methods for foveal refraction often give uncertain results in eccentric angles as a result of the large aberrations and the reduced retinal function. The aim of this study is therefore to compare and evaluate four methods for eccentric refraction. Methods. Four eccentric methods were tested on 50 healthy subjects: one novel subjective procedure, optimizing the detection contrast sensitivity with different trial lenses, and three objective ones: photorefraction with a PowerRefractor, wavefront measurements with a Hartmann-Shack sensor, and retinoscopy. The peripheral refractive error in the horizontal nasal visual field of the right eye was measured in 20 degrees and 30 degrees. Results. In general, the eccentric refraction methods compared reasonably well. However, the following differences were noted. Retinoscopy showed a significant difference from the other methods in the axis of astigmatism. In 300 eccentric angle, it was not possible to measure 15 of the subjects with the PowerRefractor and the instrument also tended to underestimate high myopia (<-6 D). The Hartmann-Shack sensor showed a myopic shift of approximately 0.5 D in both eccentricities. The subjective method had a relatively larger spread. Conclusions. This study indicates that it is possible to assess the eccentric refraction with all methods. However, the Hartmann-Shack technique was found to be the most useful method. The agreement between the objective methods and the subjective eccentric refraction shows that detection contrast sensitivity in the periphery is affected by relatively small amounts of defocus.
引用
收藏
页码:298 / 306
页数:9
相关论文
共 41 条
[1]   Effect of window size on detection acuity and resolution acuity for sinusoidal gratings in central and peripheral vision [J].
Anderson, RS ;
Evans, DW ;
Thibos, LN .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1996, 13 (04) :697-706
[2]   REFRACTION, ALIASING, AND THE ABSENCE OF MOTION REVERSALS IN PERIPHERAL-VISION [J].
ARTAL, P ;
DERRINGTON, AM ;
COLOMBO, E .
VISION RESEARCH, 1995, 35 (07) :939-947
[3]   Comparison of peripheral refractions determined by different instruments [J].
Atchison, DA .
OPTOMETRY AND VISION SCIENCE, 2003, 80 (09) :655-660
[4]   Hartmann-Shack technique and refraction across the horizontal visual field [J].
Atchison, DA ;
Scott, DH ;
Charman, WN .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2003, 20 (06) :965-973
[5]   Monochromatic aberrations of human eyes in the horizontal visual field [J].
Atchison, DA ;
Scott, DH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (11) :2180-2184
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]  
BUREK H, 1990, OPHTHAL PHYSL OPT, V10, P280, DOI 10.1111/j.1475-1313.1990.tb00864.x
[8]   Laboratory, clinical, and kindergarten test of a new eccentric infrared photorefractor (PowerRefractor) [J].
Choi, M ;
Weiss, S ;
Schaeffel, F ;
Seidemann, A ;
Howland, HC ;
Wilhelm, B ;
Wilhelm, H .
OPTOMETRY AND VISION SCIENCE, 2000, 77 (10) :537-548
[9]  
CUBALCHINI R, 1979, J OPT SOC AM, V69, P973
[10]  
Daniel M., 2006, Optical Shop Testing