Method to compare collision-induced dissociation spectra of peptides: Potential for library searching and subtractive analysis

被引:149
作者
Yates, JR
Morgan, SF
Gatlin, CL
Griffin, PR
Eng, JK
机构
[1] Univ Washington, Dept Mol Biotechnol, Seattle, WA 98195 USA
[2] Merck & Co Inc, Dept Chem, Rahway, NJ 07065 USA
关键词
D O I
10.1021/ac980122y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the development of a method to compare collision-induced dissociation (CID) spectra of peptides. This method employs a cross-correlation analysis of a CID spectrum to a reference spectrum and normalizes the cross-correlation score to the autocorrelation of the CID spectra. The query spectrum is compared by using both mass information and fragmentation patterns. Fragmentation patterns are compared to each other using a correlation function. To evaluate the specificity of the approach, a set of 2180 tandem mass spectra obtained from both triple-quadrupole tandem mass spectrometers (TSQ) and quadrupole ion trap mass spectrometers (LCQ) was created. Comparisons are performed between tandem mass spectra obtained on the same instrument type as well as between different instrument types. Accurate and reliable comparisons are demonstrated in both types of analyses. The scores obtained in the cross-comparison of TSQ and LCQ tandem mass spectra of the same peptide are found to be slightly lower than comparisons performed with spectra obtained on the same instrument type. The method appears insensitive to variations in day-to-day performance of the instrument, minor variations in fragment ion abundance, and instrumental differences inherent in the same instrument model. The use of this method of comparison is demonstrated for library searching and subtractive analysis of tandem mass spectra obtained during LC/MS/MS experiments.
引用
收藏
页码:3557 / 3565
页数:9
相关论文
共 27 条
[1]   SEQUENCING OF PEPTIDES BY TANDEM MASS-SPECTROMETRY AND HIGH-ENERGY COLLISION-INDUCED DISSOCIATION [J].
BIEMANN, K .
METHODS IN ENZYMOLOGY, 1990, 193 :455-479
[2]   INSTRUMENT DATABASE SYSTEM AND APPLICATION TO MASS-SPECTROMETRY MASS-SPECTROMETRY [J].
CRAWFORD, RW ;
BRAND, HR ;
WONG, CM ;
GREGG, HR ;
HOFFMAN, PA ;
ENKE, CG .
ANALYTICAL CHEMISTRY, 1984, 56 (07) :1121-1127
[3]   CRITICAL-EVALUATION OF CLASS-II AND CLASS-III ELECTRON-IMPACT MASS-SPECTRA - OPERATING PARAMETERS AND REPORTING MASS-SPECTRA [J].
DILLARD, JG ;
HELLER, SR ;
MCLAFFERTY, FW ;
MILNE, GWA ;
VENKATARAGHAVAN, R .
ORGANIC MASS SPECTROMETRY, 1981, 16 (01) :48-49
[4]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[5]  
Griffin P., 1991, TECHN PROT CHEM 2, V46, P477
[6]   Direct database searching with MALDI-PSD spectra of peptides [J].
Griffin, PR ;
MacCoss, MJ ;
Eng, JK ;
Blevins, RA ;
Aaronson, JS ;
Yates, JR .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (15) :1546-1551
[7]   PATTERN-BASED ALGORITHM FOR PEPTIDE SEQUENCING FROM TANDEM HIGH-ENERGY COLLISION-INDUCED DISSOCIATION MASS-SPECTRA [J].
HINES, WM ;
FALICK, AM ;
BURLINGAME, AL ;
GIBSON, BW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :326-336
[8]   DETECTION OF SPECTRAL INFORMATION UTILIZING CROSS-CORRELATION TECHNIQUES [J].
HORLICK, G .
ANALYTICAL CHEMISTRY, 1973, 45 (02) :319-324
[9]   COMPUTER-PROGRAM (SEQPEP) TO AID IN THE INTERPRETATION OF HIGH-ENERGY COLLISION TANDEM MASS-SPECTRA OF PEPTIDES [J].
JOHNSON, RS ;
BIEMANN, K .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1989, 18 (11) :945-957
[10]  
JOSEPHS J, 1997, 45 ASMS C MASS SPECT, P681