A new method for extracting cable parameters from input impedance data

被引:10
作者
Cox, SJ [1 ]
机构
[1] Rice Univ, Dept Computat & Appl Math, Houston, TX 77005 USA
关键词
D O I
10.1016/S0025-5564(98)10033-0
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
We establish conditions under which the input impedance and its first two derivatives, evaluated at the origin, uniquely determine the axial resistance, membrane capacitance, and membrane conductance of a finite uniform cable with one sealed end. We argue that these impedance data are readily available to the experimentalist and we demonstrate the recovery of a cable's electrical parameters from synthetic noisy measurements. (C) 1998 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 8 条
[1]   PASSIVE NEURONAL MEMBRANE PARAMETERS - COMPARISON OF OPTIMIZATION AND PEELING METHODS [J].
DAGUANNO, A ;
BARDAKJIAN, BL ;
CARLEN, PL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (12) :1188-1196
[2]   ESTIMATING THE ELECTROTONIC STRUCTURE OF NEURONS WITH COMPARTMENTAL-MODELS [J].
HOLMES, WR ;
RALL, W .
JOURNAL OF NEUROPHYSIOLOGY, 1992, 68 (04) :1438-1452
[3]  
JACK JJB, 1975, ELECT CURRENT FLOW E
[4]  
POZNANSKI RR, 1991, B MATH BIOL, V53, P457, DOI 10.1007/BF02460728
[5]  
Rall W., 1989, METHODS NEURONAL MOD, P9
[6]  
Rall W., 1977, HDB PHYSL NERVOUS SY, P39, DOI DOI 10.1002/CPHY.CP010103/FULL
[7]  
VU PL, 1989, MATH NACHR, V141, P325
[8]   THE PARAMETER-IDENTIFICATION PROBLEM FOR THE SOMATIC SHUNT MODEL [J].
WHITE, JA ;
MANIS, PB ;
YOUNG, ED .
BIOLOGICAL CYBERNETICS, 1992, 66 (04) :307-318