Robot-assisted fracture reduction: A preliminary study in the femur shaft

被引:84
作者
Gosling, T [1 ]
Westphal, R
Hufner, T
Faulstich, J
Kfuri, M
Wahl, F
Krettek, C
机构
[1] Hannover Med Sch, Trauma Dept, D-3000 Hannover, Germany
[2] Tech Univ Carolo Wilhelmina Braunschweig, Inst Robot & Proc Control, D-3300 Braunschweig, Germany
关键词
fracture; reduction; robot; femur; malalignment;
D O I
10.1007/BF02345131
中图分类号
TP39 [计算机的应用];
学科分类号
081203 [计算机应用技术]; 0835 [软件工程];
摘要
Reduction in femoral shaft fractures can be difficult to achieve with minimally invasive techniques. Malalignment and high intra-operative radiation exposure can result. The hypothesis was that robot-assisted fracture reduction could improve the quality of reduction while reducing the amount of radiation exposure. A robot system was developed that allows fracture manipulation with a joystick as input device. The system provides the surgeon with haptic and metric feedback. Fifteen synthetic femurs were broken and reduced by simulated open (group A) and closed techniques (group B). These techniques were compared with the robot-assisted reduction with (group C) and without (group D) haptic and metric information. An image intensifier was simulated with two orthogonal cameras. All reduction techniques showed minor malalignment. In group C, the alignment was: procurvatum/recurvaturn 0.6degrees (0-2.0degrees); varus/valgus 0.8degrees (0-3.0degrees), and axial rotation 0.8degrees (0-3.1degrees). A significant difference was seen between the groups (two-way ANOVA, p < 0.001). Axial rotation was significantly lower in group C than in group B (1.9degrees; p < 0.001). The residual varus and valgus deviation was higher in group C compared with group A (0.4degrees, p = 0.03). The median number of simulated radiographs was significantly less in group C (35) compared with group D (72, p < 0.001) and group B (49, p = 0.01). Robot-assisted fracture reduction of the femur provides high precision in alignment while reducing the amount of intra-operative imaging. Further research in this field is worthwhile.
引用
收藏
页码:115 / 120
页数:6
相关论文
共 25 条
[1]
Amarenco G, 2001, MUSCLE NERVE, V24, P116, DOI 10.1002/1097-4598(200101)24:1<116::AID-MUS16>3.0.CO
[2]
2-0
[3]
ANGLEN J, 1994, CLIN ORTHOP RELAT R, P239
[4]
Bouazza-Marouf K, 1995, Proc Inst Mech Eng H, V209, P51, DOI 10.1243/PIME_PROC_1995_209_316_02
[5]
Burkart A, 2001, Comput Aided Surg, V6, P270, DOI 10.3109/10929080109146092
[6]
A method of examining the magnitude and origin of ''soft'' and ''hard'' tissue forces resisting limb lengthening [J].
Gardner, TN ;
Evans, M ;
Simpson, AHRW ;
Kyberd, PJ ;
Kenwright, J .
MEDICAL ENGINEERING & PHYSICS, 1997, 19 (05) :405-411
[7]
Percutaneous skeletal joysticks for closed reduction of femoral shaft fractures during intramedullary nailing [J].
Georgiadis, GM ;
Burgar, AM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (08) :570-571
[8]
Gibson RJ, 2000, J TRAUMA, V48, P576, DOI 10.1097/00005373-200003000-00042
[9]
GROVER J, 1995, ORTHOP CLIN N AM, V26, P139
[10]
CT DETERMINATION OF FEMORAL TORSION [J].
HERNANDEZ, RJ ;
TACHDJIAN, MO ;
POZNANSKI, AK ;
DIAS, LS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (01) :97-101