Synthetic receptors as sensor coatings for molecules and living cells

被引:82
作者
Dickert, FL [1 ]
Hayden, O [1 ]
Halikias, KP [1 ]
机构
[1] Univ Vienna, Inst Analyt Chem, A-1090 Vienna, Austria
关键词
D O I
10.1039/b009893k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Non-covalent molecularly imprinted polymers are applied as sensitive coatings to planar waveguides and mass-sensitive devices for the selective detection of various groups of analytes in the gaseous and aqueous phases. Cavity imprinting in the bulk of the sensor material as well as surface imprinting techniques are used to enrich analytes ranging from sub-nanometres to micrometres in analyte size. The coated devices provide sensitivity to e.g. polycyclic aromatic hydrocarbons, xanthine derivatives, complex coffee samples and whole microorganisms.
引用
收藏
页码:766 / 771
页数:6
相关论文
共 22 条
[1]   Spatially functionalized polymer surfaces produced via cell-mediated lithography [J].
Alexander, C ;
Vulfson, EN .
ADVANCED MATERIALS, 1997, 9 (09) :751-755
[2]   QUARTZ-CRYSTAL MICROBALANCE SENSOR IN LIQUIDS [J].
AUGE, J ;
HAUPTMANN, P ;
EICHELBAUM, F ;
ROSLER, S .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 19 (1-3) :518-522
[3]  
Barceló D, 1999, TRAC-TREND ANAL CHEM, V18, P137
[4]  
BENES E, 1997, IEEE INT FREQ CONTR, P5
[5]   Molecularly imprinted sensor layers for the detection of polycyclic aromatic hydrocarbons in water [J].
Dickert, FL ;
Tortschanoff, M ;
Bulst, WE ;
Fischerauer, G .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4559-4563
[6]   Process control with mass-sensitive chemical sensors - Cyclodextrin modified polymers as coatings [J].
Dickert, FL ;
Tortschanoff, M ;
Weber, K ;
Zenkel, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (01) :21-24
[7]   Molecularly imprinted polymers for optochemical sensors [J].
Dickert, FL ;
Thierer, S .
ADVANCED MATERIALS, 1996, 8 (12) :987-990
[8]   Molecular imprinting in chemical sensing - Detection of aromatic and halogenated hydrocarbons as well as polar solvent vapors [J].
Dickert, FL ;
Forth, P ;
Lieberzeit, P ;
Tortschanoff, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (7-8) :759-762
[9]   SAW devices-sensitivity enhancement in going from 80 MHz to 1 GHz [J].
Dickert, FL ;
Forth, P ;
Bulst, WE ;
Fischerauer, G ;
Knauer, U .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 46 (02) :120-125
[10]   Quality control of automotive engine oils with mass-sensitive chemical sensors - QCMs and molecularly imprinted polymers [J].
Dickert, FL ;
Forth, P ;
Lieberzeit, PA ;
Voigt, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (08) :802-806