A multi-band capillary immunosensor

被引:23
作者
Misiakos, K [1 ]
Kakabakos, SE
机构
[1] NCSR Demokritos, Inst Microelect, Athens 15310, Greece
[2] NCSR Demokritos, Immunoassay Qual Control Lab, IR RP, Athens 15310, Greece
关键词
multianalyte; immunosensor; capillary waveguide;
D O I
10.1016/S0956-5663(98)00048-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In the present work we propose a new optical immunosensor based on capillary geometry and capable of multianalyte determinations. The device is made of a polystyrene capillary tube. The inner walls of the capillary are segmented into distinct bands which are coated with appropriate binding molecules. Following excitation, some of the fluorescent photons emitted by the label are trapped and waveguided into the capillary walls provided they are launched towards the walls and within the critical angle. Here, Europium-labeled streptavidin reacted with different amounts of biotinylated bovine serum albumin immobilized onto each one of the bands. Due to the small inner volume of the capillary and the multianalyte feature we expect that the proposed device can be used for fast and inexpensive assays. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:825 / 830
页数:6
相关论文
共 20 条
  • [1] OPTICAL BIOSENSORS FOR IMMUNOASSAYS - THE FLUORESCENCE CAPILLARY-FILL DEVICE
    BADLEY, RA
    DRAKE, RAL
    SHANKS, IA
    SMITH, AM
    STEPHENSON, PR
    THOMAS, JDR
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1987, 316 (1176) : 143 - 160
  • [2] Bayer E A, 1980, Methods Biochem Anal, V26, P1
  • [3] Photoactivatable silanes for the site-specific immobilization of antibodies
    Conrad, DW
    Davis, AV
    Golightley, SK
    Bart, JC
    Ligler, FS
    [J]. MICRO- AND NANOFABRICATED ELECTRO-OPTICAL MECHANICAL SYSTEMS FOR BIOMEDICAL AND ENVIRONMENTAL APPLICATIONS, PROCEEDINGS OF, 1997, 2978 : 12 - 21
  • [4] Capillary biosensor for glutamate
    Cosford, RJO
    Kuhr, WG
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (13) : 2164 - 2169
  • [5] A COMPARISON OF 3 FLUOROPHORES FOR USE IN AN OPTICAL BIOSENSOR FOR THE MEASUREMENT OF PROSTATE-SPECIFIC ANTIGEN IN WHOLE-BLOOD
    DANIELS, PB
    FLETCHER, JE
    ONEILL, PM
    STAFFORD, CG
    BACARESEHAMILTON, T
    ROBINSON, GA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1995, 27 (1-3) : 447 - 451
  • [6] AN ASSAY FOR HUMAN CHORIONIC-GONADOTROPIN USING THE CAPILLARY FILL IMMUNOSENSOR
    DEACON, JK
    THOMSON, AM
    PAGE, AL
    STOPS, JE
    ROBERTS, PR
    WHITELEY, SC
    ATTRIDGE, JW
    LOVE, CA
    ROBINSON, GA
    DAVIDSON, GP
    [J]. BIOSENSORS & BIOELECTRONICS, 1991, 6 (03) : 193 - 199
  • [7] DIAMANDIS EP, 1988, CLIN BIOCHEM, V21, P139, DOI 10.1016/0009-9120(88)90001-X
  • [8] DIAMANDIS EP, 1991, CLIN CHEM, V37, P625
  • [9] FLUORESCENCE SPECTROSCOPY AND ITS APPLICATION TO A NEW GENERATION OF HIGH-SENSITIVITY, MULTI-MICROSPOT, MULTIANALYTE, IMMUNOASSAY
    EKINS, R
    CHU, F
    BIGGART, E
    [J]. CLINICA CHIMICA ACTA, 1990, 194 (01) : 91 - 114
  • [10] USE OF AVIDIN-BIOTIN INTERACTION IN IMMUNOENZYMATIC TECHNIQUES
    GUESDON, JL
    TERNYNCK, T
    AVRAMEAS, S
    [J]. JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1979, 27 (08) : 1131 - 1139