CT-measured regional specific volume change reflects regional ventilation in supine sheep

被引:79
作者
Fuld, Matthew K. [1 ,2 ]
Easley, R. Blaine [1 ,2 ]
Saba, Osama I. [5 ]
Chon, Deokiee [5 ]
Reinhardt, Joseph M. [5 ]
Hoffman, Eric A. [4 ,5 ]
Simon, Brett A. [1 ,2 ,3 ]
机构
[1] Johns Hopkins Univ Hosp, Dept Anesthesiol, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Crit Care Med, Baltimore, MD USA
[3] Johns Hopkins Univ, Dept Med, Baltimore, MD USA
[4] Univ Iowa, Coll Med, Dept Radiol, Iowa City, IA USA
[5] Univ Iowa, Coll Med, Dept Biomed Engn, Iowa City, IA USA
关键词
multidetector-row computer tomography scanning; xenon computer tomography; implanted markers; lung mechanics;
D O I
10.1152/japplphysiol.00212.2007
中图分类号
Q4 [生理学];
学科分类号
071003 [生理学];
摘要
Computer tomography (CT) imaging techniques permit the noninvasive measurement of regional lung function. Regional specific volume change (sVol), determined from the change in lung density over a tidal breath, should correlate with regional ventilation and regional lung expansion measured with other techniques. sVol was validated against xenon (Xe)-CT-specific ventilation (sV.) in four anesthetized, intubated, mechanically ventilated sheep. Xe-CT used expiratory gated axial scanning during the washin and washout of 55% Xe. sVol was measured from the tidal changes in tissue density (H, houndsfield units) of lung regions using the relationship sVol = [1,000(Hi - He)]/[ He(1,000 + Hi)], where He and Hi are expiratory and inspiratory regional density. Distinct anatomical markings were used to define corresponding lung regions of interest between inspiratory, expiratory, and Xe-CT images, with an average region of interest size of 1.6 +/- 0.7 ml. In addition, sVol was compared with regional volume changes measured directly from the positions of implanted metal markers in an additional animal. A linear relationship between sVol and sV. was demonstrated over a wide range of regional sV. found in the normal supine lung, with an overall correlation coefficient (R-2) of 0.66. There was a tight correlation (R-2 = 0.97) between marker-measured volume changes and sVol. Regional sVol, which involves significantly reduced exposure to radiation and Xe gas compared with the Xe-CT method, represents a safe and efficient surrogate for measuring regional ventilation in experimental studies and patients.
引用
收藏
页码:1177 / 1184
页数:8
相关论文
共 32 条
[1]
Abramoff MD., 2004, Biophot. Int., V11, P36
[2]
Lung volumes before and after lung volume reduction surgery - Quantitative CT analysis [J].
Becker, MD ;
Berkmen, YM ;
Austin, JHM ;
Mun, IK ;
Romney, BM ;
Rozenshtein, A ;
Jellen, PA ;
Yip, CK ;
Thomashow, B ;
Ginsburg, ME .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 157 (05) :1593-1599
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
Differences in regional wash-in and wash-out time constants for xenon-CT ventilation studies [J].
Chon, D ;
Simon, BA ;
Beck, KC ;
Shikata, H ;
Saba, OI ;
Won, CH ;
Hoffman, EA .
RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2005, 148 (1-2) :65-83
[5]
High resolution CT in cystic fibrosis -: the contribution of expiratory scans [J].
Dorlöchter, L ;
Nes, H ;
Fluge, G ;
Rosendahl, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 47 (03) :193-198
[6]
EFFECTS OF POSITIVE END-EXPIRATORY PRESSURE ON REGIONAL DISTRIBUTION OF TIDAL VOLUME AND RECRUITMENT IN ADULT-RESPIRATORY-DISTRESS-SYNDROME [J].
GATTINONI, L ;
PELOSI, P ;
CROTTI, S ;
VALENZA, F .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 151 (06) :1807-1814
[7]
Quantification of regional ventilation from treatment planning CT [J].
Guerrero, T ;
Sanders, K ;
Noyola-Martinez, J ;
Castillo, E ;
Zhang, Y ;
Tapia, R ;
Guerra, R ;
Borghero, Y ;
Komaki, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (03) :630-634
[8]
REGIONAL PULMONARY VENTILATION MEASUREMENTS BY XENON ENHANCED DYNAMIC COMPUTED-TOMOGRAPHY - AN UPDATE [J].
GUR, D ;
SHABASON, L ;
BOROVETZ, HS ;
HERBERT, DL ;
REECE, GJ ;
KENNEDY, WH ;
SERAGO, C .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (05) :678-683
[9]
GUR D, 1979, J COMPUT ASSIST TOMO, V3, P749
[10]
Using bland-altman to assess agreement between two medical devices - Don't forget the confidence intervals! [J].
Hamilton C. ;