Estimation of indoor air PAH concentration increases by cigarette, incense-stick, and mosquito-repellent-incense smoke

被引:18
作者
Endo, O
Koyano, M
Mineki, S
Goto, S
Tanabe, K
Yajima, H
Ishii, T
Matsushita, H
机构
[1] Natl Inst Publ Hlth, Dept Community Environm Sci, Minato Ku, Tokyo 1088638, Japan
[2] Tokyo Univ Sci, Dept Appl Biol Sci, Noda, Chiba 2788510, Japan
[3] Natl Inst Environm Studies, Environm Chem Div, Tsukuba, Ibaraki 3050053, Japan
[4] Tokyo Univ Sci, Dept Appl Chem, Shinjuku Ku, Tokyo 1628601, Japan
[5] Shizuoka Inst Environm & Hyg, Shizuoka 4208637, Japan
关键词
polycyclic aromatic hydrocarbons; benzo[a]pyrene; particulate matter; indoor air pollution; smoking; incense;
D O I
10.1080/10406630008028538
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
Smoke from cigarette smoking and burning of incense sticks and mosquito-repellent incense, which is particularly used in summer, are thought to be primary factors of indoor air pollution by polycyclic aromatic hydrocarbons (PAHs) in Japanese houses. In this study, these respective smokes as indoor air pollutants were evaluated by quantifying their particulate matter (PM) and 7 PAHs. PM and PAHs in smoke from 5 popular brands of Japanese cigarettes were collected on the glass fiber filter by the international smoking mode. PM was quantified by weighing the filter before and after trapping them. PAHs were analyzed by HPLC after extracting the filter with ethanol/benzene (1.3, by vol.). Similarly, evaluation of smoke respectively generated by natural burning of 4 brands of incense sticks and 3 brands of mosquito-repellent incenses was also conducted. As the results of these experiments, the average concentrations of PM and benzo[a]pyrene in a 35 m(3) closed room were estimated to increase 1630 mug/m(3) and 8.2 ng/m(3), respectively, by smoking of 3 cigarettes, 1320 mug/m(3) and 4.1 ng/m(3), respectively, by burning of 2 incense sticks; and 2510 mug/m(3) and 17.3 ng/m(3), respectively, by burning of 8 cm of mosquito-repellent incense.
引用
收藏
页码:261 / 272
页数:12
相关论文
共 15 条
[1]  
*COMM BIOL EFF AIR, 1981, ENV POLL EFF BIOORG, V14, P14
[2]  
*EC PLANN AG BUR N, 1975, STRUCT AN LIV TIM, P23
[3]  
HANDA T, 1979, J JAPAN SOC AIR POLL, V14, P334
[4]  
*JAP ENV SAN CTR, 1991, NAT AIR SAN NETW R 2, P271
[5]  
MATSUMOTO K, 1987, ANN REPORT SENDAI CI, V17, P330
[6]  
MATSUSHITA H, 1990, ENVIR SCI R, V39, P33
[7]  
MATSUSHITA H, 1989, CURRENT ENCY PATHOLO, V10, P15
[8]  
MATSUSHITA H, 1990, INDOOR AIR QUALITY, P371
[9]  
MORI T, 1987, J JPN SOC AIR POLLUT, V22, P237
[10]   INDOOR AIR-POLLUTANTS FROM UNVENTED KEROSENE HEATER EMISSIONS IN MOBILE HOMES - STUDIES ON PARTICLES, SEMIVOLATILE ORGANICS, CARBON-MONOXIDE, AND MUTAGENICITY [J].
MUMFORD, JL ;
WILLIAMS, RW ;
WALSH, DB ;
BURTON, RM ;
SVENDSGAARD, DJ ;
CHUANG, JC ;
HOUK, VS ;
LEWTAS, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1991, 25 (10) :1732-1738