Results and repeatability of retinal thickness measurements from certification submissions

被引:14
作者
Danis, Ronald P. [1 ]
Fisher, Marian R. [2 ]
Lambert, Ericka [1 ]
Goulding, Anne [1 ]
Wu, Deborah [1 ]
Lee, Li-Yin [1 ]
机构
[1] Univ Wisconsin, Dept Ophthalmol & Visual Sci, Sch Med & Publ Hlth, Madison, WI 53711 USA
[2] Univ Wisconsin, Dept Biostat & Med Informat, Sch Med & Publ Hlth, Madison, WI 53711 USA
关键词
D O I
10.1001/archopht.126.1.45
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To present the results for subgroups defined by center point (CP) measurement and to assess the repeatability of the Fast Retinal Thickness Map analysis results from the Stratus OCT3 machine. Methods: Two hundred eighty-one replicate OCT3 scans from 134 operators' certification submissions to a reading center were analyzed, including scans from eyes that were reported to be normal and eyes with exudative age-elated macular degeneration and with macular edema due to diabetic retinopathy or retinal vascular occlusion. Results: The mean (SD) of the CP was 284 (150) mu m and the center subfield (CC) was 301 (130) mu m. The CP coefficient of repeatability (CR) was 49 mu m and the CC CR was 27 mu m. The CR increased by increasing retinal thickness for the CP and the CC within arbitrarily defined subgroups. For the 87 eyes with a session 1 CP of 175 mu m or less, the CP CR was 17 mu m and the CC CR was 10 mu m. Conclusions: Among experienced operators, given the same operator, machine, and eye at the same sitting, OCT3 retinal thickness maps appear to have a CR that is likely to be less than the clinically important difference.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 12 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Intraobserver variability in optical coherence tomography. [J].
Browning, DJ ;
Fraser, CA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (03) :477-479
[3]   Interobserver variability in optical coherence tomography for macular [J].
Browning, DJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (06) :1116-1117
[4]  
Gürses-Özden R, 2004, J GLAUCOMA, V13, P238
[5]  
Ihaka R., 1996, Journal of computational and graphical statistics, V5, P299, DOI [10.1080/10618600.1996.10474713, 10.2307/1390807]
[6]  
Koozekanani D, 2000, INVEST OPHTH VIS SCI, V41, P1486
[7]   Reproducibility of retinal mapping using optical coherence tomography [J].
Massin, P ;
Vicaut, E ;
Haouchine, B ;
Erginay, A ;
Paques, M ;
Gaudric, A .
ARCHIVES OF OPHTHALMOLOGY, 2001, 119 (08) :1135-1142
[8]  
Muscat S, 2002, INVEST OPHTH VIS SCI, V43, P490
[9]   Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT [J].
Paunescu, LA ;
Schuman, JS ;
Price, LL ;
Stark, PC ;
Beaton, S ;
Ishikawa, H ;
Wollstein, G ;
Fujimoto, JG .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (06) :1716-1724
[10]   Repeatability and reproducibility of fast macular thickness mapping with stratus optical coherence tomography [J].
Polito, A ;
Del Borrello, M ;
Isola, M ;
Zemella, N ;
Bandello, F .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (10) :1330-1337