Statistical evaluation of internal and external mass calibration laws utilized in Fourier transform ion cyclotron resonance mass spectrometry

被引:43
作者
Muddiman, DC
Oberg, AL
机构
[1] Mayo Clin, Coll Med, WM Keck FT ICR, Mass Spect Lab,Mass Proteom Res Ctr, Rochester, MN 55905 USA
[2] Mayo Clin, Coll Med, Dept Biochem & Mol Biol, Rochester, MN 55905 USA
[3] Mayo Clin, Coll Med, Div Biostat, Rochester, MN 55905 USA
关键词
D O I
10.1021/ac048258l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The statistical evaluation of two common and three new calibration laws utilized in Fourier transform ion cyclotron resonance mass spectrometry are presented. Electrospray ionization was used to prepare a series of mass spectra of ammonium-adducted polypropylene glycol (PPG) with an average molecular weight of 1000 Da. The singly charged PPG-1000 oligomers allowed for the description of a broad range of m/z and abundance values within each mass spectrum. The hexapole accumulation time was varied to afford a range of total ion abundance values of about an order of magnitude. To examine each of the calibration laws, we utilized cross-validation both "within-spectrum" and "between-spectra" for internally and externally calibrated data, respectively. In addition, we used t-statistics to ensure that each calibration coefficient was statistically significant and necessary to accurately describe the variation in the data. In comparison to commonly used calibration laws for internal calibration, our new calibration law based on multiple linear regression offered a 2-fold improvement in mass measurement accuracy (MMA). In comparison to external calibration laws without automatic gain control, our new calibration law using multiple regression improved the MMA by > 10-fold; this improvement would increase further as the dynamic range of the measurement increases (e.g., a biological system). For both our internal and external calibration laws, the median MMA was less than 1 part-per-million. Furthermore, we investigate the number of calibrant ions as well as their required m/z range in order to successfully achieve high MMA.
引用
收藏
页码:2406 / 2414
页数:9
相关论文
共 49 条
[1]   Automated gain control and internal calibration with external ion accumulation capillary liquid chromatography-electrospray ionization-fourier transform ion cyclotron resonance [J].
Belov, ME ;
Zhang, R ;
Strittmatter, EF ;
Prior, DC ;
Tang, K ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2003, 75 (16) :4195-4205
[2]  
BOGDANOV B, 2004, MASS SPECTROM REV
[3]  
BROWN S, 2004, MASS SPECTROM REV
[4]   Liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometric characterization of protein kinase C phosphorylation [J].
Chalmers, MJ ;
Quinn, JP ;
Blakney, GT ;
Emmett, MR ;
Mischak, H ;
Gaskell, SJ ;
Marshall, AG .
JOURNAL OF PROTEOME RESEARCH, 2003, 2 (04) :373-382
[5]   Role of accurate mass measurement (±10 ppm) in protein identification strategies employing MS or MS MS and database searching [J].
Clauser, KR ;
Baker, P ;
Burlingame, AL .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2871-2882
[6]   FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY [J].
COMISAROW, MB ;
MARSHALL, AG .
CHEMICAL PHYSICS LETTERS, 1974, 25 (02) :282-283
[7]   Utility of accurate mass tags for proteome-wide protein identification [J].
Conrads, TP ;
Anderson, GA ;
Veenstra, TD ;
Pasa-Tolic, L ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3349-3354
[8]  
COOPER H, 2004, MASS SPECTROM REV
[9]   Routine part-per-million mass accuracy for high-mass ions: Space-charge effects in MALDI FT-ICR [J].
Easterling, ML ;
Mize, TH ;
Amster, IJ .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :624-632
[10]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71