Trans-telephonic monitoring of continuous haemodynamic measurements in heart failure patients

被引:16
作者
Kjellström, B
Igel, D
Abraham, J
Bennett, T
Bourge, R
机构
[1] Medtronic Inc, Heart Failure Management, Minneapolis, MN 55432 USA
[2] Univ Alabama, Birmingham, AL USA
关键词
D O I
10.1258/1357633054471795
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The development of an implantable haemodynamic monitor (IHM) has made possible the home monitoring of a patient's central haemodynamic trends during daily living. We have evaluated the usability and transmission success of such a system over a 3.2-year period. Patients with an IHM were able to transmit the stored data every week to a Web server, where trend plots and tables of haemodynamic variables could be viewed by the healthcare staff concerned. Data transfer was examined from August 2000 to November 2003. During this period, 148 patients had an IHM implanted. Over the study period, 7791 data transmissions were performed and an average of 286 downloads per month were sent to the Web server. In all, 86% of data transmissions were successful, although 10% required more than one attempt. The study demonstrated that telemonitoring of haemodynamic data from an IHM was feasible. A patient survey showed that the technology was user-friendly and that the training material provided sufficient information for patients and their families to install and use the transmission equipment at home. It also suggested that transmission success was independent of patient age or gender.
引用
收藏
页码:240 / 244
页数:5
相关论文
共 9 条
  • [1] Ongoing right ventricular hemodynarnics in heart failure -: Clinical value of measurements derived from an implantable monitoring system
    Adamson, PB
    Magalski, A
    Braunschweig, F
    Böhm, M
    Reynolds, D
    Steinhaus, D
    Luby, A
    Linde, C
    Ryden, L
    Cremers, B
    Takle, T
    Bennett, T
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (04) : 565 - 571
  • [2] Einthoven W., 1906, ARCH INT PHYSIOL, V4, P132
  • [3] ACC/AHA guidelines for the evaluation and management of chronic heart failure in the adult: Executive summary - A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to revise the 1995 Guidelines for the Evaluation and Management of Heart Failure)
    Hunt, SA
    Baker, DW
    Chin, MH
    Cinquegrani, MP
    Feldman, AM
    Francis, GS
    Ganiats, TG
    Goldstein, S
    Gregoratos, G
    Jessup, ML
    Noble, RJ
    Packer, M
    Silver, MA
    Stevenson, LW
    Gibbons, RJ
    Antman, EM
    Alpert, JS
    Faxon, DP
    Fuster, V
    Gregoratos, G
    Jacobs, AK
    Hiratzka, LF
    Russell, RO
    Smith, SC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (07) : 2101 - 2113
  • [4] A systematic review of telemonitoring for the management of heart failure
    Louis, AA
    Turner, T
    Gretton, M
    Baksh, A
    Cleland, JGE
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2003, 5 (05) : 583 - 590
  • [5] Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor:: A multicenter, 12-month follow-up study of patients with chronic heart failure
    Magalski, A
    Adamson, P
    Gadler, F
    Böehm, M
    Steinhaus, D
    Reynolds, D
    Vlach, K
    Linde, C
    Cremers, B
    Sparks, B
    Bennett, T
    [J]. JOURNAL OF CARDIAC FAILURE, 2002, 8 (02) : 63 - 70
  • [6] Ohlsson A, 1995, J Card Fail, V1, P161
  • [7] Continuous ambulatory monitoring of absolute right ventricular pressure and mixed venous oxygen saturation in patients with heart failure using an implantable haemodynamic monitor -: Results of a 1 year multicentre feasibility study
    Ohlsson, Å
    Kubo, SH
    Steinhaus, D
    Connelly, DT
    Adler, S
    Bitkover, C
    Nordlander, R
    Rydén, L
    Bennett, T
    [J]. EUROPEAN HEART JOURNAL, 2001, 22 (11) : 942 - 954
  • [8] Parsonnet V, 1985, Hosp Physician, V21, p1A
  • [9] MEASUREMENT OF PULMONARY-ARTERY DIASTOLIC PRESSURE FROM THE RIGHT VENTRICLE
    REYNOLDS, DW
    BARTELT, N
    TAEPKE, R
    BENNETT, TD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (05) : 1176 - 1182