Endovascular stent grafts and aortic rupture: A case series

被引:47
作者
Karmy-Jones, R
Hoffer, E
Meissner, MH
Nicholls, S
Mattos, M
机构
[1] Univ Washington, Harborview Med Ctr, Div Cardiothorac Surg, Seattle, WA 98104 USA
[2] Univ Washington, Harborview Med Ctr, Div Intervent Radiol, Seattle, WA 98104 USA
[3] Univ Washington, Harborview Med Ctr, Div Vasc Surg, Seattle, WA 98104 USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2003年 / 55卷 / 05期
关键词
endovascular stent grafts; traumatic rupture of the aorta; endoleak; operative risk;
D O I
10.1097/01.TA.0000094429.98136.29
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. Endovascular stent grafts (EVSGs) offer an alternative in the management of traumatic rupture of the aorta, particularly in patients who are at prohibitive operative risk. Methods We conducted at retrospective review of 11 cases managed by EVSGs over a 4-year period. EVSGs were defined as "noncommercial" (graft material hand sewn over metallic stents) or "commercial" (grafts marketed for infrarenal aortic or thoracic aneurysms). Data collected included the difference between endovascular stent graft length, tear length (apposition length), and location relative to the left subclavian artery. Results: EVSGs (three noncommercial and eight commercial, including AneuRx cuff [six], Talent [one], and Ancure aortic tube graft [one]) were used in 11 patients. Six were placed less than or equal to 8 hours from injury, cone after 14 hours, three after 5 days, and one 10 years after injury. Routes of access included femoral (four), iliac (three), and abdominal aorta (four). Average landing zone diameter was 18.8 +/- 3.5 mm, distance from the left subclavian artery was 2.85 +/- 2.1 cm, and tear length was 1.54 +/- 1.0 cm. In four cases, the apposition length was less than 2 cm. There were two cases of persistent endoleak and two cases of endoleak noted and treated at deployment. Persistent endoleak occurred in two of three noncommercial EVSGs. Endoleak occurred in three of four cases when apposition length was less than 2 cm, one of which was treated successfully at the time of placement by deploying extension grafts. Endoleak occurred in two of six cases when deployment was within 2 cm of the origin of the left subclavian artery. In one case of persistent endoleak, open repair was performed 3 weeks later when the patient had stabilized. Ultimately, there were three deaths, two caused by severe closed head injury and one caused by respiratory failure. Conclusion: Endovascular stent grafts can be placed emergently. Commercial grafts result in better results than noncommercial grafts. Available "cuff extenders" are sufficient for the majority of aortic injuries but often require deployment via the iliac or aorta because of the shorter delivery system. Tears more than 1.5 cm resulting in apposition length less than 2 cm or those near or in the curvature of the aorta are associated with increased endoleak risk. The ideal thoracic EVSG would be available in 5-, 7.5-, 10-, and 15-cm lengths and mounted on a system 80 cm in length.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 12 条
  • [1] Angiographic description of blunt traumatic injuries to the thoracic aorta with specific relevance to endograft repair
    Borsa, JJ
    Hoffer, EK
    Karmy-Jones, R
    Fontaine, AB
    Bloch, RD
    Yoon, JK
    So, CR
    Meissner, MH
    Demirer, S
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 : 84 - 91
  • [2] TRANSLUMINAL PLACEMENT OF ENDOVASCULAR STENT-GRAFTS FOR THE TREATMENT OF DESCENDING THORACIC AORTIC-ANEURYSMS
    DAKE, MD
    MILLER, DC
    SEMBA, CP
    MITCHELL, RS
    WALKER, PJ
    LIDDELL, RP
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (26) : 1729 - 1734
  • [3] The "first generation" of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta
    Dake, MD
    Miller, DC
    Mitchell, RS
    Semba, CP
    Moore, KA
    Sakai, T
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (05) : 689 - 703
  • [4] Endovascular stent grafting for the treatment of blunt thoracic aortic injury
    Fujikawa, T
    Yukioka, T
    Ishimaru, S
    Kanai, M
    Muraoka, A
    Sasaki, H
    Honma, H
    Koike, S
    Kawaguchi, S
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 50 (02): : 223 - 227
  • [5] Green RM, 2003, TRENDS IN VASCULAR SURGERY, P151
  • [6] Treatment of acute thoracic aortic injury with commercially available abdominal aortic stent-grafts
    Hoffer, EK
    Karmy-Jones, R
    Bloch, RD
    Meissner, MH
    Borsa, JJ
    Nicholls, SC
    So, CR
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (10) : 1037 - 1041
  • [7] Acute and contained rupture of the descending thoracic aorta: Treatment with endovascular stent grafts
    Kato, N
    Hirano, T
    Ishida, M
    Shimono, T
    Cheng, SH
    Yada, I
    Takeda, K
    [J]. JOURNAL OF VASCULAR SURGERY, 2003, 37 (01) : 100 - 105
  • [8] Traumatic thoracic aortic aneurysm: Treatment with endovascular stent-grafts
    Kato, N
    Dake, MD
    Miller, DC
    Semba, CP
    Mitchell, RS
    Razavi, MK
    Kee, ST
    [J]. RADIOLOGY, 1997, 205 (03) : 657 - 662
  • [9] Acute traumatic aortic rupture:: early stent-graft repair
    Lachat, M
    Pfammatter, T
    Witzke, H
    Bernard, E
    Wolfensberger, U
    Künzli, A
    Turina, M
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 21 (06) : 959 - 963
  • [10] TRAUMATIC RUPTURE OF THE THORACIC AORTA - SHOULD ONE ALWAYS OPERATE IMMEDIATELY
    MAGGISANO, R
    NATHENS, A
    ALEXANDROVA, NA
    CINA, C
    BOULANGER, B
    MCKENZIE, R
    HARRISON, AW
    [J]. ANNALS OF VASCULAR SURGERY, 1995, 9 (01) : 44 - 52