Comparison of self-expanding and balloon-expandable stents for the reduction of restenosis

被引:48
作者
Han, RO
Schwartz, RS
Kobayashi, Y
Wilson, SH
Mann, JT
Sketch, MH
Safian, RD
Lansky, A
Popma, J
Fitzgerald, PJ
Palacios, IF
Chazin-Caldie, M
Goldberg, S
机构
[1] Massachusetts Gen Hosp, Div Cardiovasc, Boston, MA 02114 USA
[2] Mayo Clin, Rochester, MN USA
[3] Wake Heart Associates, Raleigh, NC USA
[4] Duke Univ, Durham, NC USA
[5] William Beaumont Hosp, Royal Oak, MI 48072 USA
[6] Washington Hosp Ctr, Washington, DC 20010 USA
[7] Brigham & Womens Hosp, Boston, MA 02115 USA
[8] Stanford Univ, Stanford, CA 94305 USA
[9] Boston Sci, Maple Grove, MN USA
[10] Cooper Univ Med Ctr, Camden, NJ USA
关键词
D O I
10.1016/S0002-9149(01)01636-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To compare the efficacy of self-expanding (SE) and balloon-expandable (BE) stents in native coronary arteries, we randomly assigned 1,096 patients with new and restenotic lesions to receive either device. Baseline demographics and coronary angiographic characteristics were similar in the 2 groups. The incidence of major adverse cardiac events including death, myocardial infarction, bypass surgery, and repeat intervention was similar for both groups at 1 month (2.9% vs 3.1% for SE vs BE, respectively) and at 9 months (19.3% vs 20.1%, SE vs BE respectively). In a subgroup of patients who underwent follow-up angiography (n = 250), the binary restenosis rates (24.2% vs 18.7%, p = 0.30), late loss (0.98 vs 94 mm, p = 0.60), and loss index (0.55 vs 55, p = 0.95) were not significantly different for both groups. In 62 patients who underwent intravascular ultrasound examination (IVUS), there was a trend toward a lower incidence of edge tears in the SE group (6% vs 23%, p = 0.06). Follow-up IVUS analysis showed that the minimum stent area of the SE stent increased by 33% at 6 months, whereas no change occurred in the BE stents; this was accompanied by a greater degree of intimal proliferation in the SE stents compared with BE stents (3.1 +/- 2.0 vs 1.7 +/- 1.7 mm(2)). Thus, the SE stents had similar clinical and angiographic outcomes in patients with lesions in native coronary arteries. (C) 2001 by Excerpta Medica, Inc.
引用
收藏
页码:253 / 259
页数:7
相关论文
共 8 条
  • [1] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [2] GREGOIRE J, 1997, HDB CORONARY STENTS, P71
  • [3] SELF-EXPANDABLE AND HIGHLY FLEXIBLE NITINOL STENT - IMMEDIATE AND LONG-TERM RESULTS IN DOGS
    GRENADIER, E
    SHOFTI, R
    BEYAR, M
    LICHTIG, H
    MORDECHOWITZ, D
    GLOBERMAN, O
    MARKIEWICZ, W
    BEYER, R
    [J]. AMERICAN HEART JOURNAL, 1994, 128 (05) : 870 - 878
  • [4] Predictive factors of restenosis after coronary stent placement
    Kastrati, A
    Schomig, A
    Elezi, S
    Schuhlen, H
    Dirschinger, J
    Hadamitzky, M
    Wehinger, A
    Hausleiter, J
    Walter, H
    Neumann, FJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (06) : 1428 - 1436
  • [5] RUYGROK P, 1997, HDB CORONARY STENTS, P1
  • [6] A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE
    SERRUYS, PW
    DEJAEGERE, P
    KIEMENEIJ, F
    MACAYA, C
    RUTSCH, W
    HEYNDRICKX, G
    EMANUELSSON, H
    MARCO, J
    LEGRAND, V
    MATERNE, P
    BELARDI, J
    SIGWART, U
    COLOMBO, A
    GOY, JJ
    VANDENHEUVEL, P
    DELCAN, J
    MOREL, MA
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 489 - 495
  • [7] A NEW INTRATRACHEAL STENT MADE FROM NITINOL, AN ALLOY WITH SHAPE-MEMORY EFFECT
    VINOGRAD, I
    KLIN, B
    BROSH, T
    WEINBERG, M
    FLOMENBLIT, Y
    NEVO, Z
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 107 (05) : 1255 - 1261
  • [8] Wayman C. M., 1972, Metal Science Journal, V6, P175