Speciation of antimony(III) and antimony(V) using hydride generation inductively coupled plasma atomic emission spectrometry combined with the rate of pre-reduction of antimony

被引:56
作者
Feng, YL
Narasaki, H [1 ]
Chen, HY
Tian, LC
机构
[1] Saitama Univ, Fac Sci, Dept Chem, Urawa, Saitama 3388570, Japan
[2] Nanjing Univ, Dept Chem, Nanjing 210093, Peoples R China
关键词
antimony; speciation; hydride generation; inductively coupled plasma atomic emission spectrometry;
D O I
10.1016/S0003-2670(99)00007-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Antimony(III) and antimony(V) were speciated by hydride generation inductively coupled plasma atomic emission spectrometry (HG-ICP-AES) based on the pre-reduction kinetics of antimony(V) to antimony(III) with L-cysteine. A linear relationship between the reduced amount of antimony(V) with 3 mg ml(-1) of L-cysteine and the reaction time was achieved within 10 min. The reduced amount of antimony(V) were determined after 2 and 8 min, respectively, by using HG-ICP-AES in this method. Mutual interferences of antimony(III) and antimony(V) were investigated. Interferences from transition metals were removed by a Chelex 100 resin column. The method was successfully applied to speciate antimony(III) and antimony(V) in spiked water samples. The detection limits of the method for antimony(III) and antimony(V) were 1.2 and 4.5 ng ml(-1) respectively. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:297 / 304
页数:8
相关论文
共 24 条
[1]   DETERMINATION OF ANTIMONY(III), ANTIMONY(V), AND METHYLANTIMONY SPECIES IN NATURAL-WATERS BY ATOMIC-ABSORPTION SPECTROMETRY WITH HYDRIDE GENERATION [J].
ANDREAE, MO ;
ASMODE, JF ;
FOSTER, P ;
VANTDACK, L .
ANALYTICAL CHEMISTRY, 1981, 53 (12) :1766-1771
[2]   Hydride generation interface for the determination of inorganic arsenic and organoarsenic by inductively coupled plasma mass spectrometry using open-focused microwave digestion to enhance the pre-reduction process [J].
Beauchemin, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (01) :1-5
[3]  
CASTILLO JR, 1986, MIKROCHIM ACTA, V3, P95
[4]   COMBINED GENERATOR SEPARATOR .2. STIBINE GENERATION COMBINED WITH FLOW-INJECTION FOR THE DETERMINATION OF ANTIMONY IN METAL SAMPLES BY ATOMIC EMISSION-SPECTROMETRY [J].
CHEN, HW ;
BRINDLE, ID ;
ZHENG, SG .
ANALYST, 1992, 117 (10) :1603-1608
[5]   SIMULTANEOUS DETERMINATION OF INORGANIC ARSENIC AND ANTIMONY SPECIES IN NATURAL-WATERS USING SELECTIVE HYDRIDE GENERATION WITH GAS-CHROMATOGRAPHY PHOTOIONIZATION DETECTION [J].
CUTTER, LS ;
CUTTER, GA ;
SANDIEGOMCGLONE, MLC .
ANALYTICAL CHEMISTRY, 1991, 63 (11) :1138-1142
[6]   DETERMINATION OF TOTAL AVAILABLE ANTIMONY IN MARINE-SEDIMENTS BY SLURRY FORMATION HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY - APPLICABILITY TO THE SELECTIVE DETERMINATION OF ANTIMONY(III) AND ANTIMONY(V) [J].
DELACALLEGUNTINAS, MB ;
MADRID, Y ;
CAMARA, C .
ANALYST, 1991, 116 (10) :1029-1032
[7]   SIMULTANEOUS DETERMINATION OF ARSENIC(V) AND ARSENIC(III) IN WATER BY INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY USING REDUCTION OF ARSENIC(V) BY L-CYSTEINE AND A SMALL CO-CENTRIC HYDRIDE GENERATOR WITHOUT A GAS-LIQUID SEPARATOR [J].
FENG, YL ;
CAO, JP .
ANALYTICA CHIMICA ACTA, 1994, 293 (1-2) :211-218
[8]   Off-line separation and determination of inorganic arsenic species in natural water by high resolution inductively coupled plasma mass spectrometry with hydride generation combined with reaction of arsenic(V) and L-cysteine [J].
Feng, YL ;
Chen, HY ;
Tian, LC ;
Narasaki, H .
ANALYTICA CHIMICA ACTA, 1998, 375 (1-2) :167-175
[9]  
Gallignani M., 1990, J BRAZIL CHEM SOC, V1, P72
[10]   Determination of antimony species with high-performance liquid chromatography using element specific detection [J].
Lintschinger, J ;
Koch, I ;
Serves, S ;
Feldmann, J ;
Cullen, WR .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (06) :484-491