A large outbreak of Legionnaires' disease due to an inadequate circulating and filtration system for bath water - Epidemiologic manifestations

被引:35
作者
Nakamura, H
Yagyu, H
Kishi, K
Tsuchida, F
Oh-Ishi, S
Yamaguchi, K
Matsuoka, T
机构
[1] Tokyo Med Univ, Dept Internal Med 5, Ibaraki 3000395, Japan
[2] Toho Univ, Sch Med, Dept Microbiol, Tokyo, Japan
关键词
Legionnaires' disease; large outbreak; public bathhouse; circulating bath water system; molecular epidemiology; LEGIONELLA-PNEUMOPHILA; PNEUMONIA; SPECIMENS; SPA;
D O I
10.2169/internalmedicine.42.806
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To study the epidemiologic manifestations of a large outbreak of Legionnaires' disease due to an inadequate circulating and filtration system for bath water. Patients In June 2000 at Ishioka City, lbaraki Prefecture, a large outbreak of Legionnaire's disease occurred, as a result of an inadequate circulating and filtration system for communal bath water. This outbreak was the worst ever experienced in Japan, involving a total of 34 patients (20 confirmed, 14 probable), 3 of whom died. Measurements and Results Legionella pneumophila serogroup I was isolated from sputum culture in two patients. Bacteriological culture of the public bath water subsequently yielded large numbers of Legionella species. Cleavage of genomic DNA showed that restriction fragment patterns coming from clinical and environmental isolates of L. pneumophila serogroup I were closely related, focusing the inquiry to a public bathhouse where a circulating filtration system was suspected as the source of infection. Conclusions It was later concluded that the circulating filtration system adopted for bath water was marred by a serious design flaw that subsequently caused the mass outbreak. Specifically, a line of the bath water was being returned to the bath without undergoing heat exchange or sterilization by chlorine; and the Legionella species that had proliferated in the filter and the bright stone filtration unit were allowed to return to the bath, eventually culminating in a mass infection.
引用
收藏
页码:806 / 811
页数:6
相关论文
共 17 条
[1]  
Arbeit R. D., 1999, MANUAL CLIN MICROBIO, P116
[2]   EXPOSURE TO LEGIONELLACEAE AT A HOT-SPRING SPA - A PROSPECTIVE CLINICAL AND SEROLOGICAL STUDY [J].
BORNSTEIN, N ;
MARMET, D ;
SURGOT, M ;
NOWICKI, M ;
ARSLAN, A ;
ESTEVE, J ;
FLEURETTE, J .
EPIDEMIOLOGY AND INFECTION, 1989, 102 (01) :31-36
[3]  
*CDC, 1997, MMWR-MORBID MORTAL W, V46, P83
[4]   Detection of Legionella species in respiratory specimens using PCR with sequencing confirmation [J].
Cloud, JL ;
Carroll, KC ;
Pixton, P ;
Erali, M ;
Hillyard, DR .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (05) :1709-1712
[5]   IMPROVED SEMISELECTIVE MEDIUM FOR ISOLATION OF LEGIONELLA-PNEUMOPHILA FROM CONTAMINATED CLINICAL AND ENVIRONMENTAL SPECIMENS [J].
EDELSTEIN, PH .
JOURNAL OF CLINICAL MICROBIOLOGY, 1981, 14 (03) :298-303
[6]   SPORADIC LEGIONELLOSIS IN THE UNITED-STATES - THE 1ST THOUSAND CASES [J].
ENGLAND, AC ;
FRASER, DW ;
PLIKAYTIS, BD ;
TSAI, TF ;
STORCH, G ;
BROOME, CV .
ANNALS OF INTERNAL MEDICINE, 1981, 94 (02) :164-170
[7]   EVALUATION OF THE MICROPLATE HYBRIDIZATION METHOD FOR RAPID IDENTIFICATION OF LEGIONELLA SPECIES [J].
EZAKI, T ;
HASHIMOTO, Y ;
YAMAMOTO, H ;
LUCIDA, ML ;
LIU, SL ;
KUSUNOKI, S ;
ASANO, K ;
YABUUCHI, E .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1990, 9 (03) :213-217
[8]   LEGIONNAIRES DISEASE - DESCRIPTION OF AN EPIDEMIC OF PNEUMONIA [J].
FRASER, DW ;
TSAI, TR ;
ORENSTEIN, W ;
PARKIN, WE ;
BEECHAM, HJ ;
SHARRAR, RG ;
HARRIS, J ;
MALLISON, GF ;
MARTIN, SM ;
MCDADE, JE ;
SHEPARD, CC ;
BRACHMAN, PS .
NEW ENGLAND JOURNAL OF MEDICINE, 1977, 297 (22) :1189-1197
[9]   Detection of Legionella pneumophila antigen in urine samples by the BinaxNOW immunochromatographic assay and comparison with both Binax Legionella Urinary Enzyme Immunoassay (EIA) and Biotest Legionella urinary antigen EIA [J].
Helbig, JH ;
Uldum, SA ;
Lück, PC ;
Harrison, TG .
JOURNAL OF MEDICAL MICROBIOLOGY, 2001, 50 (06) :509-516
[10]   Outbreak of Legionnaires' disease among cruise ship passengers exposed to a contaminated whirlpool spa [J].
Jernigan, DB ;
Hofmann, J ;
Cetron, MS ;
Genese, CA ;
Nuorti, JP ;
Fields, BS ;
Benson, RF ;
Carter, RJ ;
Edelstein, PH ;
Guerrero, IC ;
Paul, SM ;
Lipman, HB ;
Breiman, RF .
LANCET, 1996, 347 (9000) :494-499