Dosimetric characteristics of an improved radiochromic film

被引:130
作者
Meigooni, AS [1 ]
Sanders, MF [1 ]
Ibbott, GS [1 ]
Szeglin, SR [1 ]
机构
[1] NUCL ASSOCIATES, CARLE PL, NY 11514 USA
关键词
radiochromic film; GafChromic film; dosimeter; film; detector;
D O I
10.1118/1.597747
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, a new model of radiochromic film has been developed for medical applications to provide a higher sensitivity and better uniformity of response than existing models (i.e., MD-55). Dosimetric characteristics including sensitivity, linearity, reproducibility, uniformity, and dependence on energy and time have been studied experimentally. The characteristics of the new films were compared with those of model MD-55. For these investigations, the two films were exposed to ionizing radiation in the dose range from 1-72 Gy, using gamma-rays from a Co-60 teletherapy unit and 6- and 18-MV x rays from a linear accelerator. The response of the exposed film was measured with a helium-neon laser densitometer. The results indicated that the sensitivity of the improved film was about 40% greater than that of MD-55 film. Moreover, the response of the improved film was found to be uniform within 4% only in one direction of the film. The orthogonal direction indicated a nonuniformity of up to 15%, similar to that of model MD-55. Less than 5% energy dependence in the megavoltage photon range was observed for the new film. Complete dosimetric characteristics of the new film are presented. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:1883 / 1888
页数:6
相关论文
共 23 条
[1]   HIGH-SENSITIVITY GAFCHROMIC FILM DOSIMETRY FOR I-125 SEED [J].
CHIUTSAO, ST ;
DELAZERDA, A ;
LIN, J ;
KIM, JH .
MEDICAL PHYSICS, 1994, 21 (05) :651-657
[2]  
CHU RDH, 1990, RADIAT PHYS CHEM, V35, P767
[3]   CHARACTERIZATION OF A MULTILEAF COLLIMATOR SYSTEM [J].
GALVIN, JM ;
SMITH, AR ;
LALLY, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (02) :181-192
[4]   DYE FILM DOSIMETRY FOR RADIATION PROCESSING [J].
HUMPHREYS, JC ;
MCLAUGHLIN, WL .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (02) :1797-1801
[5]   MEASUREMENTS OF DOSE DISTRIBUTIONS IN VARIOUS MATERIALS IRRADIATED BY 10-MEV ELECTRONS [J].
HUMPHREYS, JC ;
CHAPPELL, SE ;
MCLAUGHLIN, WL ;
JARRETT, RD .
RADIATION PHYSICS AND CHEMISTRY, 1977, 9 (4-6) :749-761
[6]   THE EFFECTS OF HUMIDITY ON THE RESPONSE OF RADIOCHROMIC FILM DOSIMETERS FWT-60-00 AND GAFCHROMIC-DM-1260 [J].
JANOVSKY, I ;
MEHTA, K .
RADIATION PHYSICS AND CHEMISTRY, 1994, 43 (04) :407-409
[7]   QUANTITATIVE VERIFICATION OF IR-192 PDR AND HDR SOURCE STRUCTURE BY PINHOLE AUTORADIOGRAPHY [J].
KIROV, AS ;
MEIGOONI, AS ;
ZHU, Y ;
VALICENTI, RK ;
WILLIAMSON, JF .
MEDICAL PHYSICS, 1995, 22 (11) :1753-1757
[8]  
MCLAUGHLIN W, 1996, RADIOCHROMIC SOLID S, P152
[9]  
McLaughlin W. L., 1970, Manual on radiation dosimetry, P377
[10]   CHEMICAL DOSIMETER FOR MONITORING GAMMA RADIATION DOSED OF 1-100 KRAD [J].
MCLAUGHLIN, WL ;
HUSSMANN, EK ;
EISENLOHR, HH ;
CHALKLEY, L .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1971, 22 (03) :135-+