Parallel column liquid chromatography with a single multi-wavelength absorbance detector for enhanced selectivity using chemometric analysis

被引:13
作者
Gross, GM [1 ]
Prazen, BJ [1 ]
Synovec, RE [1 ]
机构
[1] Univ Washington, Dept Chem, Ctr Proc Analyt Chem, Seattle, WA 98195 USA
关键词
parallel column; HPLC; selectivity; generalized rank annihilation method; complementary stationary phases;
D O I
10.1016/S0003-2670(03)00669-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The selectivity of high performance liquid chromatography (HPLC) separations is increased using a parallel column configuration. In this system, an injected sample is first split between two HPLC columns that provide complementary separations. The effluent from the two columns is recombined prior to detection with a single multiwavelength absorbance detector. Complementary stationary phases are used so that each chemical component produces a detected concentration profile consisting of two peaks. A parallel column configuration, when coupled with multivariate detection, provides increased chemical selectivity relative to a single column configuration with the same multivariate detection. This enhanced selectivity is achieved by doubling the number of peaks in the chromatographic dimension while keeping the run time constant. Unlike traditional single column separation methodology, the parallel column system sacrifices chromatographic resolution while actually increasing the chemical selectivity, thus allowing chemometric data analysis methods to mathematically resolve the multivariate chromatographic data. The parallel column system can be used to reduce analysis times for partially resolved peaks and simplify initial method development as well as provide a more robust methodology if and when subsequent changes in the sample matrix occur (such as when new interferences show up in subsequent samples). Here, a mixture of common aromatic compounds were separated with this system and analyzed using the generalized rank annihilation method (GRAM). Analytes that were significantly overlapped on both stationary phases applied, ZirChrom PBD and CARB phases, when used in traditional single column format, were successfully quantified with a R.S.D.% of typically 2% when the same stationary phases were used in the parallel column format. These results indicate that a parallel column system should substantially improve the chemical selectivity and quantitative precision of the analysis relative to a single-column instrument. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:197 / 210
页数:14
相关论文
共 33 条
[1]   CORRELATION OF QUANTITATIVE-ANALYSIS PRECISION TO RETENTION TIME PRECISION AND CHROMATOGRAPHIC RESOLUTION FOR RAPID, SHORT COLUMN ANALYSIS [J].
BAHOWICK, TJ ;
SYNOVEC, RE .
ANALYTICAL CHEMISTRY, 1995, 67 (03) :631-640
[2]   EXTENSION OF TRILINEAR DECOMPOSITION METHOD WITH AN APPLICATION TO THE FLOW PROBE SENSOR [J].
BOOKSH, KS ;
LIN, ZH ;
WANG, ZY ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :2561-2569
[3]   Comprehensive two dimensional high-speed gas chromatography with chemometric analysis [J].
Bruckner, CA ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2796-2804
[4]   Translating third-order data analysis methods to chemical batch processes [J].
Dahl, KS ;
Piovoso, MJ ;
Kosanovich, KA .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 46 (02) :161-180
[5]  
Davis JM, 1997, J MICROCOLUMN SEP, V9, P193, DOI 10.1002/(SICI)1520-667X(1997)9:3<193::AID-MCS8>3.0.CO
[6]  
2-X
[7]  
DAVIS JM, 1983, ANAL CHEM, V55, P418, DOI 10.1021/ac00254a003
[8]   GENERALIZED RANK ANNIHILATION METHOD .1. DERIVATION OF EIGENVALUE PROBLEMS [J].
FABER, NM ;
BUYDENS, LMC ;
KATEMAN, G .
JOURNAL OF CHEMOMETRICS, 1994, 8 (02) :147-154
[9]   Comprehensive two-dimensional gas chromatography and chemometrics for the high-speed quantitative analysis of aromatic isomers in a jet fuel using the standard addition method and an objective retention time alignment algorithm [J].
Fraga, CG ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4154-4162
[10]  
Fraga CG, 2000, HRC-J HIGH RES CHROM, V23, P215