摘要
When considering the design of a PV/thermal system, determination of the ratio of the values of the electrical and thermal output from the system allows a rational approach to design optimisation via the minimization of 'equivalent electrical levelised energy cost'. This paper focuses on methods that can be employed to develop a ratio between electrical and thermal output from a domestic style PV/thermal system. Methods discussed include thermodynamic analysis using exergy; market analysis for both an open market and a renewable energy market; and environmental analysis using avoided greenhouse gas emissions. Ratios are developed for each method based on real data. It is concluded that a renewable energy market approach seems most logical for such a system, and an indicative value of 4.24 is obtained. An example is given comparing a PV/thermal system that uses amorphous silicon cells with one that uses crystalline silicon cells. Levelised energy cost is plotted against the energy value ratio to show that there is a critical electrical-to-thermal energy value ratio below which a collector with a-Si cells is more cost effective than one with c-Si cells. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:63 / 72
页数:10
相关论文
共 32 条
  • [1] AKALIN MT, 1978, ASHRAE T 2, V84
  • [2] [Anonymous], ISES SOL WORLD C AD
  • [3] [Anonymous], 1976, ASHRAE T
  • [4] *AUSTR GAS ASS, 2001, GAS DEF
  • [5] *AUSTR GAS ASS, 2000, GAS STAT AUSTR 2000, P73
  • [6] Bejan A., 1995, THERMAL DESIGN OPTIM
  • [7] Bucher K, 1995, 13 EUR PHOT SOL EN C, P2097
  • [8] COVENTRY J, 2001, TRNSYS COMPONENTS DE
  • [9] COVENTRY J, 2002, ANZSES SOL EN C NEWC
  • [10] CRAWFORD RH, 2000, NET ENERGY ANAL HOT