Gas/solid partitioning of semivolatile organic compounds (SOCs) to air filters. 3. An analysis of gas adsorption artifacts in measurements of atmospheric SOCs and organic carbon (OC) when using Teflon membrane filters and quartz fiber filters

被引:139
作者
Mader, BT [1 ]
Pankow, JF [1 ]
机构
[1] Oregon Grad Inst, Dept Environm Sci & Engn, Portland, OR 97291 USA
关键词
D O I
10.1021/es0015951
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Adsorption of gaseous semivolatile organic compounds (SOCs) onto the filter(s) of a filter/sorbent sampler is a potential source of measurement error when determining specific, SOCs as well as organic carbon (OC)levels in the atmosphere. This work examines partitioning to both Teflon membrane filters (TMFs) and quartz fiber filters (QFFS) for purposes of predicting the magnitude of the compound-dependent gas adsorption artifact as a function of various sampling parameters. The examination is based on values of K-p,K-face (m(3) cm(-2)), the gas/filter partition coefficient expressed as [ng sorbed per cm(2) of filter face]/[ng per m(3) in the gas phase]. Values of K(p,face)were calculated based on literature values of the gas/solid partition coefficient K-p,K-s [ng sorbed per m(2) of filter]/[ng per m(3) in gas phase] for the adsorption of various polycyclic aromatic hydrocarbons (PAHs), polychlorinated dibenzodioxins (PCDDs), and polychlorinated dibenzofurans (PCDFs) to TMFs, and for the adsorption of PAHs to QFFs. At relative humidity (RH) values below approximate to 50%, the K-p,K-face values for PAHs are lower on TMFs than on ambient-backup QFFs. The gas adsorption artifact will therefore be lower for PAHs with TMFs than with QFFs under these conditions. In the past, corrections for the gas/filter adsorption artifact have been made by using a backup filter, and subtracting the mass amount of each compound found on the backup filter from the total (particle phase + sorbed on filter) amount found on the front filter. This procedure assumes that the ng cm(-2) amounts of each SOC sorbed on the front and backup filters are equal. That assumption will only be valid after both filters have reached equilibrium with each of the gaseous SOCs in the incoming sample air. The front filter will reach equilibrium first. The minimum air sample volume V-min,V-f+b required to reach gas/filter sorption equilibrium with a pair of filters is 2K(p,face)A(filter) where A(filter) (cm(2)) is the per-filter face area. K-p,K-face values, and therefore V-min,V-f+b values, depend on the compound, relative humidity (RH), temperature, and filter type. Compound-dependent V-min,V-f+b values are presented for PAHs and PCDD/Fs on both TMFs and QFFs. Compound-dependent equations which give the magnitude of the filter adsorption artifact are presented for a range of different sampling arrangements and circumstances The equations are not intended for use in actually correcting field data because of uncertainties in actual field values of relevant parameters such as the compound-dependent K-p,K-face and gas/particle K-p values, and because of the fact that the equations assume ideal step-function chromatographic movement of gas-phase compounds through the adsorbing filter. Rather, the main utility of the equations is as guidance tools in designing field sampling efforts that utilize filter/sorbent samplers and in evaluating prior work. The results indicate that some backup-filter-based corrections described in the literature were carried out using sample volumes that were too small to allow proper correction for the gas adsorption artifact for some specific SOCs of interest. Similar conclusions are reached regarding artifacts associated with the measurement of gaseous and particulate OC.
引用
收藏
页码:3422 / 3432
页数:11
相关论文
共 23 条