Simultaneous kinetic determination of Fe(II) and Fe(III) based on their reactions with NQT4S in micellar media by using PLS and PCR methods

被引:20
作者
Absalan, G [1 ]
Nekoeinia, M [1 ]
机构
[1] Shiraz Univ, Fac Sci, Dept Chem, Shiraz 71454, Iran
关键词
simultaneous determination; speciation; partial least squares; micellar media;
D O I
10.1016/j.aca.2004.10.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Simultaneous determination of Fe(II) and Fe(III) was studied using partial least squares regression (PLS) and principal component regression (PCR) methods. The models were based on the difference observed in the rates of the complex formation of iron in its two oxidation states with 1,2-naphthaquinone-2-thiosemicarbazone-4-sulphonic acid (NQT4S) at pH 4.0 in cetyltrimethylammoniumbromide (CTAB) as micellar media. The results showed that simultaneous determination of Fe(II) and Fe(III) could be performed in their concentration ranges of 0.10-2.10 and 0.25-2.25 mug/ml, respectively. The models used can proceed the data with low percent relative error of prediction (i.e. <5.5%). The procedure was successfully applied for the simultaneous determination of Fe(II) and Fe(III) in some environmental samples. The method would allow the transformation of the two oxidation states of iron to be monitored overtime in a water sample. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:293 / 298
页数:6
相关论文
共 36 条
[1]   Simultaneous spectrophotometric determination of chromium(VI) and iron(III) with chromogenic mixed reagents by H-point standard addition method and partial least squares regression [J].
Abdollahi, H .
ANALYTICA CHIMICA ACTA, 2001, 442 (02) :327-336
[2]   SIMULTANEOUS DETERMINATION OF IRON(II) AND IRON(III) IN AQUEOUS-SOLUTION BY KINETIC SPECTROPHOTOMETRY WITH TIRON [J].
ABE, S ;
SAITO, T ;
SUDA, M .
ANALYTICA CHIMICA ACTA, 1986, 181 :203-209
[3]   KINETIC SPECTROPHOTOMETRIC METHOD FOR ANALYZING MIXTURES OF METAL-IONS BY STOPPED-FLOW INJECTION-ANALYSIS USING PARTIAL LEAST-SQUARES REGRESSION [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
RIBA, J .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2905-2911
[4]   KINETIC SPECTROPHOTOMETRIC DETERMINATION OF GA(III)-AL(III) MIXTURES BY STOPPED-FLOW INJECTION-ANALYSIS USING PRINCIPAL COMPONENT REGRESSION [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
RIBA, J ;
ROVIRA, E .
TALANTA, 1993, 40 (02) :261-267
[5]   PARTIAL LEAST-SQUARES REGRESSION FOR MULTICOMPONENT KINETIC DETERMINATIONS IN LINEAR AND NONLINEAR-SYSTEMS [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
REDON, M .
ANALYTICA CHIMICA ACTA, 1995, 303 (2-3) :309-320
[6]   COLOR CHANGES IN SCREENED INDICATORS [J].
BOSCH, E ;
CASASSAS, E ;
IZQUIERDO, A ;
ROSES, M .
ANALYTICAL CHEMISTRY, 1984, 56 (08) :1422-1428
[7]   2ND-ORDER GLOBALIZATION FOR THE DETERMINATION OF ACTIVATION PARAMETERS IN KINETICS [J].
BUGNON, P ;
CHOTTARD, JC ;
JESTIN, JL ;
JUNG, B ;
LAURENCZY, G ;
MAEDER, M ;
MERBACH, AE ;
ZUBERBUHLER, AD .
ANALYTICA CHIMICA ACTA, 1994, 298 (02) :193-201
[8]   STOPPED-FLOW KINETIC DETERMINATION OF ACETAMINOPHEN BY OXIDATION WITH A 1,10-PHENANTHROLINE-IRON(III) COMPLEX [J].
CARMONA, M ;
SILVA, M ;
PEREZBENDITO, D .
ANALYTICA CHIMICA ACTA, 1989, 218 (02) :313-322
[9]   Organic microheterogeneous systems in kinetic analysis. Self-assembled systems a review [J].
Carreto, ML ;
Rubio, S ;
PerezBendito, D .
ANALYST, 1996, 121 (04) :R33-R44
[10]   STUDIES ON METAL SPECIATION IN THE NATURAL-ENVIRONMENT [J].
CHAKRABARTI, CL ;
LU, YJ ;
CHENG, JG ;
BACK, MH ;
SCHROEDER, WH .
ANALYTICA CHIMICA ACTA, 1993, 276 (01) :47-64