Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup

被引:65
作者
Hasegawa, M [1 ]
Sudo, A [1 ]
Hirata, H [1 ]
Uchida, A [1 ]
机构
[1] Mie Univ, Fac Med, Dept Orthopaed Surg, Tsu, Mie 5148507, Japan
关键词
alumina ceramics; fracture; total hip arthroplasty; modular acetabular component; complication;
D O I
10.1016/S0883-5403(03)00193-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In total hip arthroplasty, a modular acetabular component with a sandwich insertion (alumina ceramics/polyethylene/titanium) was proposed. The polyethylene layer might reduce the rigidity of the ceramics and prevent an impingement between the ceramic liner rim and the femoral neck. A case of an acetabular liner fracture of the ceramic sandwich cup was presented. The fracture occurred 1.4 years after the operation without trauma. Because the ceramic liner rim was hit by the head following the impingement between the neck and the polyethylene, the cause of the fracture might be the stress concentration at the rim of the ceramic liner, of which the thickness was only 4 mm. At revision surgery, the fractured ceramic liner was replaced with a polyethylene liner without inner ceramic liner.
引用
收藏
页码:658 / 661
页数:4
相关论文
共 11 条
[1]
[Anonymous], SEMIN ARTHROPLAST
[2]
Bizot P, 2000, CLIN ORTHOP RELAT R, P134
[3]
THE USE OF DENSE ALUMINA ALUMINA CERAMIC COMBINATION IN TOTAL HIP-REPLACEMENT [J].
BOUTIN, P ;
CHRISTEL, P ;
DORLOT, JM ;
MEUNIER, A ;
DEROQUANCOURT, A ;
BLANQUAERT, D ;
HERMAN, S ;
SEDEL, L ;
WITVOET, J .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (12) :1203-1232
[4]
New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty [J].
D'Antonio, J ;
Capello, W ;
Manley, M ;
Bierbaum, B .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :390-397
[5]
Fritsch EW, 1996, CLIN ORTHOP RELAT R, P129
[6]
Garino JP, 2000, CLIN ORTHOP RELAT R, P41
[7]
Fracture of an alumina ceramic head in total hip arthroplasty [J].
Higuchi, F ;
Shiba, N ;
Inoue, A ;
Wakebe, I .
JOURNAL OF ARTHROPLASTY, 1995, 10 (06) :851-854
[8]
Spontaneous fracture of the ceramic ball in a ceramic-polyethylene total hip arthroplasty [J].
Michaud, RJ ;
Rashad, SY .
JOURNAL OF ARTHROPLASTY, 1995, 10 (06) :863-867
[9]
Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns [J].
Nevelos, J ;
Ingham, E ;
Doyle, C ;
Streicher, R ;
Nevelos, A ;
Walter, W ;
Fisher, J .
JOURNAL OF ARTHROPLASTY, 2000, 15 (06) :793-795
[10]
Fracture of a ceramic femoral head after a revision operation - A case report [J].
Pulliam, IT ;
Trousdale, RT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (01) :118-121