Wireless Measurement System for Structural Health Monitoring With High Time-Synchronization Accuracy

被引:77
作者
Araujo, Alvaro [1 ]
Garcia-Palacios, Jaime [2 ]
Blesa, Javier [1 ]
Tirado, Francisco [2 ]
Romero, Elena [1 ]
Samartin, Avelino [2 ]
Nieto-Taladriz, Octavio [1 ]
机构
[1] Univ Politecn Madrid, Dept Elect Engn, E-28040 Madrid, Spain
[2] Univ Politecn Madrid, Dept Civil Engn, E-28040 Madrid, Spain
关键词
Embedded computing; structural health monitoring (SHM); synchronization; telemetry; wireless sensor;
D O I
10.1109/TIM.2011.2170889
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Structural health monitoring (SHM) systems have excellent potential to improve the regular operation and maintenance of structures. Wireless networks (WNs) have been used to avoid the high cost of traditional generic wired systems. The most important limitation of SHM wireless systems is time-synchronization accuracy, scalability, and reliability. A complete wireless system for structural identification under environmental load is designed, implemented, deployed, and tested on three different real bridges. Our contribution ranges from the hardware to the graphical front end. System goal is to avoid the main limitations of WNs for SHM particularly in regard to reliability, scalability, and synchronization. We reduce spatial jitter to 125 ns, far below the 120 mu s required for high-precision acquisition systems and much better than the 10-mu s current solutions, without adding complexity. The system is scalable to a large number of nodes to allow for dense sensor coverage of real-world structures, only limited by a compromise between measurement length and mandatory time to obtain the final result. The system addresses a myriad of problems encountered in a real deployment under difficult conditions, rather than a simulation or laboratory test bed.
引用
收藏
页码:801 / 810
页数:10
相关论文
共 14 条
[1]  
[Anonymous], 2004, Proceedings of International Conference on Embedded Networked Sensor Systems (Sensys), DOI [10.1145/1031495.1031501, DOI 10.1145/1031495.1031501]
[2]  
[Anonymous], 2003, Proceedings of the 1st International Conference on Embedded Networks Sensor Systems (SenSys'03), DOI DOI 10.1145/958491.958508
[3]  
Bocca M, 2011, COMPUT-AIDED CIV INF, V26, DOI [10.1111/j.1467-8667.2011.00718.x/abstract, DOI 10.1111/J.1467-8667.2011.00718.X/ABSTRACT]
[4]  
Ceriotti M, 2009, 2009 INTERNATIONAL CONFERENCE ON INFORMATION PROCESSING IN SENSOR NETWORKS (IPSN 2009), P277
[5]   Fine-grained network time synchronization using reference broadcasts [J].
Elson, J ;
Girod, L ;
Estrin, D .
USENIX ASSOCIATION PROCEEDINGS OF THE FIFTH SYMPOSIUM ON OPERATING SYSTEMS DESIGN AND IMPLEMENTATION, 2002, :147-163
[6]   Health monitoring of civil infrastructures using wireless sensor networks [J].
Kim, Sukun ;
Pakzad, Shamim ;
Culler, David ;
Demmel, James ;
Fenves, Gregory ;
Glaser, Steven ;
Turon, Martin .
PROCEEDINGS OF THE SIXTH INTERNATIONAL SYMPOSIUM ON INFORMATION PROCESSING IN SENSOR NETWORKS, 2007, :254-263
[7]  
Kiremidjian AS, 1997, STRUCTURAL HEALT H MONITORING, P371
[8]   The effect of time synchronization of wireless sensors on the modal analysis of structures [J].
Krishnamurthy, V. ;
Fowler, K. ;
Sazonov, E. .
SMART MATERIALS & STRUCTURES, 2008, 17 (05)
[9]  
Lynch J. P., 2006, Shock and Vibration Digest, V38, P91, DOI 10.1177/0583102406061499
[10]   Finite element model updating and structural damage identification using OMAX data [J].
Reynders, Edwin ;
Teughels, Anne ;
De Roeck, Guido .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2010, 24 (05) :1306-1323