A new microparticle size calibration standard for use in measuring smaller microparticles using a new flow cytometer

被引:214
作者
Chandler, W. L. [1 ]
Yeung, W. [1 ]
Tait, J. F. [1 ]
机构
[1] Univ Washington, Dept Lab Med, Seattle, WA 98195 USA
关键词
flow cytometry; microparticles; platelets; CIRCULATING MICROPARTICLES; REFRACTIVE-INDEX; VOLUME; PLATELETS; BACTERIA; VESICLES; SCATTER;
D O I
10.1111/j.1538-7836.2011.04283.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Microparticle size measurements are often calibrated on flow cytometers using polystyrene microspheres that forward scatter more light vs. particle diameter than cellular microparticles. Methods: We compared theoretical with measured forward angle light scattering on the LSRII, FC500 and Apogee A40 using polystyrene and silica microspheres vs. synthetic lipid vesicles and platelets, then compared plasma microparticle counts using different calibration strategies. Results: Polystyrene and silica microspheres with higher refractive indices forward scattered more light with a wavelength of 488 nm for a given size microparticle than did lipid vesicles or platelets. The LSRII and FC500 did not count many, and were unable to separate by size, polystyrene microspheres < 0.5 mu m in diameter. On the Apogee A40, polystyrene microspheres could be separated by size down to 0.2 mu m, and a polystyrene microsphere 0.4 mu m in diameter produced the same forward scatter relative intensity as a 1-mu m lipid or cellular microparticle. Using the new calibrator, the Apogee A40 found 80 000-4 000 000 mu L-1 total microparticles, 11 000-350 000 mu L-1 annexin V positive microparticles and 6000-350 000 mu L-1 platelet microparticles < 1 mu m in plasma samples. Conclusions: The Apogee A40 was able to resolve size differences in polystyrene microspheres down to 0.2 mu m and microparticles down to 0.4 mu m. On the Apogee A40 we propose using a 0.4-mu m polystyrene microsphere as equivalent to a 1-mu m cellular microparticle for size calibration. Using this calibrator, the Apogee A40 detected higher numbers of total, platelet and annexin V positive microparticles than were found using a Megamix gate.
引用
收藏
页码:1216 / 1224
页数:9
相关论文
共 27 条
  • [1] Assessment of platelet activation in several different anticoagulants by the Advia 120 Hematology System, fluorescence flow cytometry, and electron microscopy
    Ahnadi, CE
    Chapman, ES
    Lépine, M
    Okrongly, D
    Pujol-Moix, N
    Hernández, A
    Boughrassa, F
    Grant, AM
    [J]. THROMBOSIS AND HAEMOSTASIS, 2003, 90 (05) : 940 - 948
  • [2] Human cell-derived microparticles promote thrombus formation in vivo in a tissue factor-dependent manner
    Biró, É
    Sturk-Maquelin, KN
    Vogel, GMT
    Meuleman, DG
    Smit, MJ
    Hack, CE
    Sturk, A
    Nieuwland, R
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2003, 1 (12) : 2561 - 2568
  • [3] The majority of circulating platelet-derived microparticles fail to bind annexin V, lack phospholipid-dependent procoagulant activity and demonstrate greater expression of glycoprotein Ib
    Connor, David Ewan
    Exner, Thomas
    Ma, David Dang Fung
    Joseph, Joanne Emily
    [J]. THROMBOSIS AND HAEMOSTASIS, 2010, 103 (05) : 1044 - 1052
  • [4] Detection and measurement of microparticles: An evolving research tool for vascular biology
    Enjeti, Anoop K.
    Lincz, Lisa F.
    Seldon, Michael
    [J]. SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2007, 33 (08) : 771 - 779
  • [5] Microparticles in Health and Disease
    Enjeti, Anoop K.
    Lincz, Lisa F.
    Seldon, Michael
    [J]. SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2008, 34 (07) : 683 - 691
  • [6] Use of silica microspheres having refractive index similar to bacteria for conversion of flow cytometric forward light scatter into biovolume
    Foladori, Paola
    Quaranta, Alberto
    Ziglio, Giuliano
    [J]. WATER RESEARCH, 2008, 42 (14) : 3757 - 3766
  • [7] Formation of procoagulant microparticles and properties
    Freyssinet, Jean-Marie
    Toti, Florence
    [J]. THROMBOSIS RESEARCH, 2010, 125 : S46 - S48
  • [8] Heijnen Harry F. G., 1999, Blood, V94, P3791
  • [9] Morphological analysis of microparticle generation in heparin-induced thrombocytopenia
    Hughes, M
    Hayward, CPM
    Warkentin, TE
    Horsewood, P
    Chorneyko, KA
    Kelton, JG
    [J]. BLOOD, 2000, 96 (01) : 188 - 194
  • [10] Deduction of the cell volume and mass from forward scatter intensity of bacteria analyzed by flow cytometry
    Koch, AL
    Robertson, BR
    Button, DK
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 1996, 27 (01) : 49 - 61