Experience with external quality control in spermatology

被引:70
作者
Cooper, TG
Atkinson, AD
Nieschlag, E
机构
[1] Univ Munster, Inst Reprod Med, D-48129 Munster, Germany
[2] St Marys Hosp, Sub Fertil Lab, Manchester M13 0JH, Lancs, England
关键词
andrology; quality control; ring trials; semen analysis; spermatology;
D O I
10.1093/humrep/14.3.765
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Results are presented from participation in an external quality control (EQC) programme for semen analysis (UK NEQAS). Formalin-fixed semen samples and videotapes of motile spermatozoa were distributed four times a year over a 3-4 year period. Over the entire period there was close agreement for sperm concentration with, initially, the average of values from the other groups participating in the scheme, and later, values designated as reference values obtained from six laboratories of several chosen that consistently agreed with each other. The initial underestimation of the percentage of normal forms was abolished at the time of change in derivation of designated values and this largely eliminated the difference to establish closer agreement with the designated values. A consistent bias in the assessment of different categories of progressive sperm motility appeared to be resolved by a conscious decision to consider most spermatozoa as grade b and the exceptions as grade a, rather than the converse. Feedback of results to the technicians of the laboratory participating in an external quality control programme leads to reappraisal of subjective evaluation and to harmonization of results between laboratories.
引用
收藏
页码:765 / 769
页数:5
相关论文
共 20 条
  • [1] CHONG AP, 1983, J ANDROL, V4, P280
  • [2] COOPER TG, 1992, FERTIL STERIL, V58, P172
  • [3] News from the European Academy of Andrology (EAA) - Implementation of quality control in the andrology laboratory
    Cooper, TG
    [J]. INTERNATIONAL JOURNAL OF ANDROLOGY, 1996, 19 (02): : 67 - 68
  • [4] ESHRE Andrology Special Interest Grp, 1998, HUM REPROD, V13, P142
  • [5] THE VALUE OF SPERM SWIMMING SPEED MEASUREMENTS IN ASSESSING THE FERTILITY OF HUMAN FROZEN-SEMEN
    HOLT, WV
    SHENFIELD, F
    LEONARD, T
    HARTMAN, TD
    NORTH, RD
    MOORE, HDM
    [J]. HUMAN REPRODUCTION, 1989, 4 (03) : 292 - 297
  • [6] HOLT WV, 1985, FERTIL STERIL, V44, P112
  • [7] Attitudes to clinical andrology: A time for change
    Jequier, AM
    Cummins, JM
    [J]. HUMAN REPRODUCTION, 1997, 12 (05) : 875 - 876
  • [8] Semen analysis performed by different laboratory teams: an intervariation study
    Jorgensen, N
    Auger, J
    Giwercman, A
    Irvine, DS
    Jensen, TK
    Jouannet, P
    Keiding, N
    LeBon, C
    MacDonald, E
    Pekuri, AM
    Scheike, T
    Simonsen, M
    Suominen, J
    Skakkebaek, NE
    [J]. INTERNATIONAL JOURNAL OF ANDROLOGY, 1997, 20 (04): : 201 - 208
  • [9] ASSESSMENT OF THE CONVENTIONAL CRITERIA OF SEMEN QUALITY BY COMPUTER-ASSISTED IMAGE-ANALYSIS - EVALUATION OF THE HAMILTON-THORN MOTILITY ANALYZER IN THE CONTEXT OF A SERVICE ANDROLOGY LABORATORY
    MACLEOD, IC
    IRVINE, DS
    MASTERTON, A
    TAYLOR, N
    TEMPLETON, AA
    [J]. HUMAN REPRODUCTION, 1994, 9 (02) : 310 - 319
  • [10] MATSON PL, 1995, HUM REPROD, V10, P620