Hemolysis rates in blood samples: differences between blood collected by clinicians and nurses and the effect of phlebotomy training

被引:28
作者
Cadamuro, Janne [1 ]
von Meyer, Alexander [2 ]
Wiedemann, Helmut [1 ]
Felder, Thomas Klaus [1 ]
Moser, Franziska [3 ]
Kipman, Ulrike [4 ]
Haschke-Becher, Elisabeth [1 ]
Mrazek, Cornelia [1 ]
Simundic, Ana-Maria [5 ]
机构
[1] Paracelsus Med Univ, Dept Lab Med, Mullner Hauptstr 48, A-5020 Salzburg, Austria
[2] Kliniken Nordoberpfalz AG, Inst Lab Med, Weiden, Germany
[3] Paracelsus Med Univ, Nursing, Salzburg, Austria
[4] UT SPSS Stat, Hallein, Austria
[5] Univ Hosp Sveti Duh, Dept Med Lab Diagnost, Zagreb, Croatia
关键词
blood collection; hemolysis; phlebotomy; preanalytics; PREANALYTICAL QUALITY; WORKING GROUP; ERRORS; EMERGENCY; INDEX; CHEMISTRY; SPECIMENS; EDUCATION; REDUCE; DRAWN;
D O I
10.1515/cclm-2016-0175
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Hemolytic samples are one of the most challenging preanalytical issues in laboratory medicine. Even causes leading to hemolytic specimen are various, including phlebotomy practices. Respective educational interventions as well as the reduction of the number of people involved in blood collections are claimed to influence the sample quality for the better. In our hospital 70 junior doctors were in charge of routine phlebotomy until 2012, when this task was shifted to 874 nurses, including a preceding training in phlebotomy and preanalytics. Our aim was to evaluate the impact of this training effect and the increase of people involved on sample quality. Methods: The hemolysis index (HI) of 43,875 samples was measured before (n = 21,512) and after (n = 22,363) the switch of blood collection responsibilities. Differences in overall hemolysis rates and the amount of plasma samples with a concentration of free hemoglobin (fHb) above 0.5 g/L and 1 g/L were calculated. Results: Overall HI as well as the percentage of samples with an fHb concentration >0.5 g/L decreased after the responsibility for phlebotomy changed. The rate of samples with an fHb concentration >1 g/L remained unchanged. Conclusions: Hemolysis rates were reduced upon passing phlebotomy tasks from untrained physicians on to a trained nursing staff. We therefore conclude that the number of people performing phlebotomy seems to play a minor role, compared to the effect of a standardized training. However, whether a reduction in the number of people involved in blood collection could lead to further improvement of sample quality, remains to be investigated in future studies.
引用
收藏
页码:1987 / 1992
页数:6
相关论文
共 40 条
[1]   RETRACTED: Preanalytical Quality in Clinical Chemistry Laboratory (Retracted Article) [J].
Ahmad, M. Imteyaz ;
Ramesh, K. L. ;
Kumar, Ravi .
CLINICAL LABORATORY, 2014, 60 (01) :87-92
[2]   Preanalytical quality control program -: an overview of results (2001-2005 summary) [J].
Alsina, M. Jesus ;
Alvarez, Virtudes ;
Barba, Nuria ;
Bullich, Sandra ;
Cortes, Mariano ;
Escoda, Irene ;
Martinez-Bru, Cecilia .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (06) :849-854
[3]  
[Anonymous], FOCUS DIAGNOSTICA
[4]  
[Anonymous], J LAB MED
[5]  
[Anonymous], 2007, PROC COLL DIAGN BLOO
[6]   Minor improvement of venous blood specimen collection practices in primary health care after a large-scale educational intervention [J].
Bolenius, Karin ;
Soderberg, Johan ;
Hultdin, Johan ;
Lindkvist, Marie ;
Brulin, Christine ;
Grankvist, Kjell .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (02) :303-310
[7]   Hemolysis in serum samples drawn by emergency department personnel versus laboratory phlebotomists [J].
Burns, ER ;
Yoshikawa, N .
LABORATORY MEDICINE, 2002, 33 (05) :378-380
[8]  
Cadamuro J, 2015, PREEXAMINATION PROCE, P345, DOI DOI 10.1515/9783110334043-040
[9]  
Cadamuro J, 2016, LABORATORIUMSMEDIZIN, V40, P49, DOI 10.1515/labmed-2015-0078
[10]   A survey of some pre-analytical errors identified from the Biochemistry Department of a Scottish hospital [J].
Davidson, D. Fraser .
SCOTTISH MEDICAL JOURNAL, 2014, 59 (02) :91-94